OP000755
Operation
3-6
5.
Turn starter switch to the "I" (ON) position (Figure 12).
When preheat cycle is completed, the preheat indicator
light (1, Figure 13) will turn "OFF."
6.
Rotate starter key to "START" position. Starter motor
should crank immediately, and engine should start within a
few seconds.
7.
Release starter key when engine starts. Key will return to
"I" (ON) position.
8.
After engine starts, check all indicator lights and gauges to
be certain that all engine systems (oil pressure, oil
temperature, coolant temperature, etc.) are in normal
operating range. If any engine system is not normal, turn
starter key to "O" (OFF) position.
9.
Perform “Hydraulic System Warm-up – Cold Weather” on
FG000084
O
I
Figure 12
CHECK
1
FG013059
Figure 13
FG000085
O
I
Figure 14
FG003899
O
I
Figure 15
IMPORTANT
If engine does not start after approximately fifteen
seconds of cranking, release starter key. Wait five
minutes for starter motor to cool down. Repeat step 6.