OP000756
Inspection, Maintenance and Adjustment
4-24
Check Hydraulic System Oil Level
1.
Move machine to a level area and shut down engine.
2.
Apply parking brake.
3.
Lower bucket to ground.
4.
Check sight gauge (Figure 17) that is attached to hydraulic
oil tank. Oil level must be between upper limit and lower
limit shown on gauge.
NOTE:
Hydraulic oil tank is located in front frame.
5.
To add hydraulic oil, remove the air breather cap (Figure
18).
6.
Add oil through the air breather cap to proper level by
checking sight glass (Figure 17).
The hydraulic oil fill cover also serves as the hydraulic oil
strainer access cover. It is important to replace this cover and
the components in the proper order and alignment.
The filter (2, Figure 19), retaining rod (3) and spring (4) are
assembled as shown in Figure 19. The hole (1) in the base of
the filter fits over a circular base in the bottom of the tank. The
retaining rod (3) screws into the top of the filter (2), but the
spring (4) slides over the top of the rod. Be certain that this
spring does not fall into the tank during reassembly.
1.
If filter assembly was removed, insert assembly into the
tank and check to make sure it is securely in place.
2.
Check O-ring for damages and replace if necessary.
Check position of O-ring at surface of hole.
WARNING!
The hydraulic oil will be hot after normal machine
operation. Allow the system to cool before attempting to
service any of the hydraulic components.
The hydraulic tank is pressurized. Loosen the cap of
breather to allow the pressurized air to vent. After the
pressure has been released, it is safe to remove either the
fill cap or service covers.
Figure 17
Figure 18
IMPORTANT
Do not fill above "HIGH" mark on sight gauge.
Overfilling can result in damage to equipment and oil
leaking from hydraulic tank due to expansion.
3
4
2
1
FG002188
Figure 19
Содержание DL160
Страница 2: ......
Страница 3: ...K1040196E I I Presentation 1Presentation PRESENTATION FG013087 Figure 1 ...
Страница 12: ...K1040196E Table of Contents IV ...
Страница 17: ...OP000753 1 5 Safety FG013042 1 3 10 12 6 4 11 5 9 8 3 7 10 4 6 2 Figure 1 ...
Страница 60: ...OP000753 Safety 1 48 ...
Страница 103: ...OP000754 2 43 Operating Controls CD Player Optional AST DIR FG000109 Figure 90 ...
Страница 216: ...OP000756 Inspection Maintenance and Adjustment 4 86 ...
Страница 226: ...OP000040 Troubleshooting 6 8 ...