6.7 Troubleshooting guide
6.7.1 Malfunctions and irregularities
•
The following are the primary, reasonably foreseeable malfunctioning conditions related to operating functions
on the
“DGT” drive units
or
endcarriages
.
PROBLEM
POSSIBLE CAUSES
A single “DGT” Unit or Beam won’t start
•
motor power cable
•
motor malfunction
•
blocked brake
•
reducer jammed
•
blocked wheel
The pair of “DGT” “DGT” Units or Beams won’t start
•
motor power cable
•
motor fuses
•
temperature sensors tripped (if available)
•
forward/reverse limit switch
•
forward/reverse contactor
•
forward/reverse command button
The driving operation won’t stop in the required space
•
worn out brake
The driving operation won’t stop at the end of the stroke
•
worn out brake
•
limit stroke operation
The reducer is excessively noisy
•
lack of lubricant
•
incorrect/overly intense operation
•
unsuitable rail tolerances (planarity/parallelism)
Grating brake sound during braking
•
check for dust
•
excessive play
•
worn out brake lining
Strident noise from the wheels (advancing in jolts)
•
incorrect play between wheel and rail way
•
unsuitable rail tolerances (planarity/parallelism)
•
incorrect/overly intense operation
The “DGT” Units or Beams start up too slowly or
uneasily and do not transfer the maximum load
•
voltage malfunction
•
overload, incorrect/overly intense operation
•
a reducer is beginning to jam
•
incorrect contact between rail and wheel
•
unsuitable rail tolerances (planarity/parallelism)
The “DGT” Units or Beams skid on the rails
•
obstacles on the rail way
•
oil, grease or paint on the rail way
•
unsuitable rail tolerances (planarity)