RF Baghouse, Models RFWP and RFWPH
56
boltsafe bolt
tubesheet
threaded insert
filter bag
filter cage
top flange
center seam on long side
of oval tubesheet hole
Felt Bag and Cage and Pleated Bag with Boltsafe
Hardware Filter Installation
Felt Bag and Cage with Boltsafe™
Hardware Filter Installation
1. Slide the filter bag onto the filter cage until the top edge of
the bag reaches the top flange of the filter cage.
Note: Place the bottom seam of the bag parallel to
the long side of the oval.
2. From the clean-air plenum, insert the filter bag and filter
cage assembly through the tubesheet aligning the two
bolts with the two threaded inserts factory installed in the
tubesheet.
3. Secure with Boltsafe bolts provided.
Hand-start each bolt before
tightening either bolt. Do not use
a power or impact driver to tighten bolts. A
speed wrench using a maximum of 20 ft/lb is
recommended.
Pleated Bag with Boltsafe™ Hardware Filter
Installation
1. From the clean air plenum, insert pleated bag assembly
through the tubesheet aligning the two bolts with the
threaded inserts in the tubesheet. It may be necessary
to squeeze the pleated bag as it is inserted into the
tubesheet.
2. Secure with Boltsafe bolts provided.
Hand-start each bolt before
tightening either bolt. Do no
use a power or impact drive to tighten bolts. A
speed wrench using a maximum of 20 ft/lb is
recommended.
Pleated Bag with Boltsafe™ Hardware Filter
Removal
1. Properly shutdown the system and lock out electrical
system.
2. Access clean air plenum through door.
3. Unscrew bolts (2) from each pleated bag.
4. Remove pleated bag.