Machines that have a water inlet use it to lower the temperature in the drum, if certain conditions are
reached, until the temperature is safe. The connection specifications are as follows:
Water dispensing system
Pipework size:
3/4 in
Minimum and Maximum supply
29 (200)
72.5 (500)
psi
(kPa)
3.2 (12)
13.2 (50)
Gal/min (L/min)
Water must be the only agent to be used when the water dispensing system is activated.
9.
ALARMS AND WARNINGS
In the Touch control, the different alarms and warnings are displayed on screen with a brief description.
When any of these alarms is triggered: 3, 4, 6, 8, 9, 14, 15, 16, 17, 18, 19, 21, 22, 23 and 24, the
machine enters an alarm mode which permits a progressive reduction of the internal temperature of the
dryer and the fabrics to prevent damage to the materials and prevent burns. This cooling lasts 10
minutes. After this time the machine stops but the alarm remains on until it is duly cancelled. The alarm
mode cooling can be cancelled by cancelling the alarm.
Before starting the machine, an initial check of the alarms 1, 2, 5, 8, 9, 12, 14, 15, 16, 17, 18, 19, 20 and
27 is made. If any of these are on, the machine cannot be started.
WARNING: ELECTRICAL SHOCK HAZARD
Electrical shock can result in death or serious injury.
If the water dispensing system is activated do not attempt
to operate the dryer.
If the water dispensing system is activated have the dryer
inspected by a qualified agency before operating the dryer.