PSS5000/TEMA/803046/14
93 of 155
PSS 5000 – Technical Manual
8 Diagnostics (Menu 5)
5.
From the list of test functions, select the function to be activated:
6.
Click
ACTIVATE
to start the selected test function.
The PSS 5000 replies with a message that informs you which function is
activated.
Device Test menu
description for Terminal
Text Test
The PSS 5000 has a built-in text bank. This makes it possible to show different
texts in the terminal’s display. The actual text in the text bank changes depend-
ing on which application programs are installed. The text in the text bank can
be viewed in the Appendix (
*.apx)
file released with the application program.
The texts in the text bank are indexed. The individual texts can be sent to the
terminals display either by a command from the POS or by using a device on
the forecourt, which is handled automatically by the PSS 5000.
Instead of sending commands from a POS, or using the devices on the fore-
court, the Terminal Text Test provides an easy method to check that the texts
are shown correctly on the terminal display.
It is possible to have up to 6 different languages in the text bank. Each lan-
guage is indexed. So, it is possible to replace an unwanted language with one
that is required for the specific application.
Test function
Description
None
Returns to normal system mode.
Reset VR counters for fuelling point
All Vapor Recovery counters for all the
nozzles belonging to the selected fuel-
ling point are reset.
Suspend disabling of fuelling point
Disabling of the fuelling point is suspend-
ed temporarily.
Simulate VR error on fuelling point
Simulate a vapor recovery error on the
selected fuelling point.
Simulate VR disabling on fuelling point
Simulate vapor recovery disabling on the
selected fuelling point.
Simulate VR disabling on nozzle
n
Simulate vapor recovery disabling of a
specific nozzle on the fuelling point.