PSS5000/TEMA/803046/14
PSS 5000 – Technical Manual
5 Installation (Menu 2)
Note:
When a Super Master Reset takes place on the PSS 5000, all the pass-
words are reset to their default settings.
Passwords can only be changed by the
admin
user, and all fixed passwords
must have 4 – 16 characters. Passwords may consist of lower case letters, up-
per case letters and digits only.
On a clean CPU board without any LAM, only the
admin
user is accepted.
All users can also have a dynamic password of the day. This can be obtained
from the system administrator.
Note:
3 incorrect password attempts will block access for one minute. Hereaf-
ter, only one attempt is accepted per minute until a successfully log on
with a correct password is achieved.
To change the user
password with web
service pages
This procedure describes how to use the Service Menu in the web browser to
change the user password for the PSS 5000.
Note:
This procedure describes what is available when an
admin
user is logged
on.
User
Description
admin
This is used by the PSS system administrator and has
all privileges:
•
Read everything
•
Change all settings
•
Perform Reset, Master Reset and Super Master
Reset
•
Upload software
•
Change passwords for other users
host
This is used by host applications (e.g. Doms Site Info)
to access the PSS 5000 (read & write) via Doms Host
Protocol.
service
This provides the privileges needed by service techni-
cians:
•
Read everything
•
Start embedded peeper to create traces
•
Perform Reset, Master Reset and Super Master
Reset
manager
This provides Read only access to all information and
access to change Prices.
guest
This provides Read only access to all information.
vrc
This is used by Vapor Recovery System administra-
tors. This user name is only supported in applications,
where Vapor Recovery Controller functionality runs on
the PSS 5000.
POS
This is used by POS applications via the Doms POS
Protocol. POS users are able to lock and clear transac-
tions.