PSS5000/TEMA/803046/14
PSS 5000 – Technical Manual
5 Installation (Menu 2)
Note:
If you typed in a value that is outside the permitted range, a message
indicating the valid range appears. You must correct the value(s).
The
Protocol to Port Assignment
window appears.
Note:
The parameter changes are not applied until the next steps.
5.
In the
Protocol to Port Assignment
window verify that all the values are cor-
rect before you continue to the next step.
6.
In the
Protocol to Port Assignment
window click
Save Changes
to apply the
changes.
Note:
If you do not wish to apply the changes, click
Discard Changes
.
7.
In the confirmation window, click
OK
The changes are saved and the PSS 5000 is Master Reset.
5.1.3
Limitations
List of areas with
limitations
Not all protocol to port assignments are possible. There can be a number of
reasons why an assignment is not possible. The user interface, which is built
to prevent the user from making illegal assignments, reduces the selectable op-
tions (reduced drop-down lists on the web service). Some of the limitations are
explained in the table below:
Note:
All TCP/IP protocols are fixed.
Protocols
Explanation
Protocols regarding DMB
Some protocols do not support addressable de-
vices. To overcome this limitation a multiplexed
port must be used.
IFSF protocols
Generally, IFSF protocols run on PSS 5000 Port
31 (LON). However, some variants run on Port
41 (TCP/IP).
Single instance protocols
Some protocols cannot be assigned to more
than one port (for example, a log printer proto-
col).
Special protocols
Some protocols need special UART features.
For example:
•
Gilbarco pump (5787 baud)
•
Satam 008 pump (900 baud)
•
Scheidt & Bachmann T02 pump
•
MKS ER 3/2 pump
Due to PSS 5000 hardware limitations, it is not
possible to run 2 of the protocols listed above
on a PSS port pair that share UART hardware.
The port pairs are:
•
port 13 + 21
•
port 14 +22
•
port 15 +23
For example, if one of the protocols listed above
is assigned to port 13, you will not be able to as-
sign any of the protocols listed to port 21.
Point to Point
PPP connections are only available on the DMB
ports. And only one DMB port can be configured
to use PPP.