20
4445103799
Determine the cable cross-section
MT LB 30
MT LB 2412-25
MT LB 2412-45
Connection variant for motor homes that are to be
equipped with a house battery and charging
device (standard connection variant).
I
➤
Install the charging booster in the connection
between the starting battery and the house bat-
tery.
➤
Disconnect the existing charging cable at a suit-
able point.
➤
To connect the charging booster proceed as
Connection variant B (fig.
Connection variant for motor homes with an exist-
ing cutoff relay.
I
➤
Install the charging booster between the exist-
ing cutoff relay (
2
) and the house battery.
➤
Disconnect the existing charging cable at a suit-
able point.
➤
To connect the charging booster proceed as
Connection variant C (MT LB 30 only)
(fig.
Connection variant for motor homes with existing
central electrical system equipped with integrated
cutoff relay and integrated charger.
I
➤
Install the charging booster in the starting bat-
tery cable between central electrical system (
2
)
and the starting battery.
Cable
cross-
section
Cable
length
START
(IN) to
starting
battery
Cable
fuse
ΙΙ
Cable
length
BORD
(OUT) to
house
battery
Cable
fuse
Ι
4 mm²
–
40 A/
50 A
0.5 m –
1.5 m
30 A/
40 A
6 mm²
< 4 m
40 A/
50 A
1.5 m –
3.0 m
30 A/
40 A
10 mm²
< 7 m
40 A/
50 A
3 m –
5.5 m
30 A/
40 A
Cable
cross-
section
Cable
length
START
(IN) to
starting
battery
Cable
fuse
ΙΙ
Cable
length
BORD
(OUT) to
house
battery
Cable
fuse
Ι
4 mm²
–
30 A
0.5 m –
2.0 m
30 A
6 mm²
< 11 m
30 A
1.5 m –
3.5 m
30 A
10 mm²
< 18 m
30 A
3.0 m –
6.5 m
30 A
Cable
cross-
section
Cable
length
START
(IN) to
starting
battery
Cable
fuse
ΙΙ
Cable
length
BORD
(OUT) to
house
battery
Cable
fuse
Ι
6 mm²
–
40 A
0.5 m –
2.0 m
50 A
10 mm²
< 10 m
40 A
1.5 m –
3.5 m
50 A
16 mm²
< 16 m
40 A
3.0 m –
5.0 m
50 A
NOTE
The charging booster replaces an exist-
ing cut-off relay. Use connection variant B
if the cut-off relay cannot be removed.
NOTE
The charging booster replaces an exist-
ing cut-off relay. Use connection
variant A if the cut-off relay can be
removed.
NOTE
For LiFePO4 batteries: Disable the inte-
grated charger if it is not equipped with
temperature-controlled charging and
the charging characteristic for LiFePO4
batteries.
Содержание BUTTNER MT LB2412-25
Страница 4: ...4 4445103799 3 2 1 100 mm 100 mm 4 5...
Страница 5: ...4445103799 5 2 1 3 90 6 2 3 5 m 4 5 5 m 1 5 m 7...
Страница 7: ...4445103799 7 START Sense START D Kl 15 EBL Start In BORD Sense BORD Temp Sensor D Kl 15 10 A 3 A A 1 c...
Страница 8: ...8 4445103799 B START Sense START D Kl 15 EBL Start In BORD Sense BORD Temp Sensor 3 A 10 A D 2 1 d...
Страница 11: ...4445103799 11 223 270 5 74 g...