50, programmable for one time or with the time limit
Timings for Code Entry:
10 seconds waiting for next digit entry
The Timers:
Three 1-99,999 Seconds (Over 24 Hours possible) Independent Programmable Timers for
O/P 1, 2 & 3
Egress Button:
Programmable for Instant, Delay with Warning and/or Alarm
Momentary or Holding Contact for the Exit Delay
Input Sensing Terminals:
a)
Door position,
b)
Egress,
c)
O/P 1 inhibit
Output Control Terminals:
Transistor Open Collector 24VDC/100mA sink Max for the following outputs
a)
Duress,
b)
Alarm,
c)
Key Active,
d)
Output 3 (Door Bell version only),
e)
Inter-lock
Output Contact Ratings:
Output Relay 1 – N.C. & N.O. dry contacts, 5A/24VDC Max.
Output Relay 2 – N.C. & N.O. dry contacts, 1A/24VDC Max.
Output Relay 3 – N.C. & N.O. dry contacts, 1A/24VDC Max. (N.O. contact only for Door Bell
version)
Tamper Switch – N.C. dry contact, 50mA/24VDC Max.
Dimensions:
DOLKSF1KB – 4 3/4(H) X 3 1/8(W) X 2(D) inches
Weight:
DOLKSF1KB – 1 lb net
Housing:
Cast aluminum, power paint coating outer box & plastic inner box
Faceplate Material:
1/16 inch stainless steel
Specifications are subject to change for modification without notice
DOLKSF1KB QUICK START GUIDE
As the DOLKSF1KB is powered, it will begin its booting process and beep for 1 minute. When the
DOLKSF1KB is finished:
1.
Enter: [Master Code], *, * (Default [Master Code]: 0000)
1.
Enter: 01, [Your new 4-8 digit Master Code], #
2.
Enter: 102000 [Unique 4-8 digit Access Code], #
3.
Enter: 102001 [Unique 4-8 digit Access Code], #
4.
Enter: 102002 [Unique 4-8 digit Access Code], #...
5.
Enter: *, *
6.
To gain access: Enter the Unique 4-8 digit Access Code followed by the # key.
Содержание dolksf1kb
Страница 1: ...USER MANUAL Single Gang Flush Mount Keypad DOLKSF1KB V 3 6 18...
Страница 2: ......