Normally closed while the keypad is secured on its box. It is open when keypad is
separated from its box. Connect this to an alarm system if necessary.
•
10-12: O/P 2 OR BELL (Output Relay 2)
•
10 (Normally closed)
•
Use 10 for equipment that requires a constant flow of electricity to function
properly. Ex. Magnetic locks, receivers, etc.
•
11 (Common ground)
•
12 (Normally open)
•
Use 12 for equipment that requires a temporary surge of electricity to activate. Ex.
Electric door locks, automated gates, etc.
•
13: O/P 3 (Output Relay 3 N.O.)
•
Output 3 is a normally open terminal
•
14: DOOR SENS N.C. (Door Position Sensing Input -- Normally Closed)
•
DOOR SENS must be connecting to ground if not used. This feature can be connected
to a normally closed device (ex. A magnet) to sense a door’s status (being opened or
closed). With DOOR SENS connected, the following features are possible:
•
Door Auto Re-lock
•
The system will immediately lock after a door/gate has been opened and closed.
•
Door Forced Open Warning
•
The system will signal a warning and trigger Alarm Output once the door is
forced open without a valid access code or egress button. The warning signal
lasts as long as programmed. Entering an output 1 code will deactivate the
warning signal.
•
Open Door Warning
•
The door will signal a warning if the door is left open for longer than the
programmed time.
•
Interlock Control
•
The Interlock Control is a two-keypad, two-door feature and it will disable the
other keypad as long as its door is open and the keypads are connected by O/P 1
INHIBIT and INT LOCK.
•
Open Door Alarm
•
Open Door Alarm is designed for the emergency door. When the door is opened
without a valid access code or egress button, the alarm will trigger. The warning
signal lasts as long as programmed.
•
15: (-) GND (Common Ground)
•
16: O/P 1 INHIBIT (Output 1 Inhibit Control Input – Normally Open)
•
This is used for the dual keypad feature. It is normally open but will disable the keypad
when closed. This is used in conjunction with INT LOCK.
•
NOTE: The inhibit function does not govern the Duress Codes and the Authorization
Codes. These are always valid.
•
17: INT LOCK (Inter-lock Control Output)
•
This is used for the dual keypad feature. Connect this to the other keypad’s O/P 1
INHIBIT.
•
18: K OR A O/P (Keypad Active or Alarm Output)
•
When any key is pressed, the K OR A O/P will switch to ground for 10 seconds. Ex. It
may be used to turn on a light, camera, or buzzer for 10 seconds the moment a button
is pressed. It may also be used to trigger an alarm for a security system. Be sure to
switch the jumper to K or A located on the upper-left corner of the circuit board.
•
LED Indicators
•
Red
•
This becomes a solid color when Access Lock is activated. It is also the Wiegand
LED in reader mode
•
Yellow