access code or egress button, the
alarm will trigger. Important Note:
Either "Door Forced Open" or
"Open Door Alarm" can be
activated. Both features should not
be activated together
Disable Open Door
Alarm Timing
910#
Egress Settings
Single press, no warning
901, [Activation Delay seconds: 0-99], #
Pressing the egress button will
silently grant access
Single press, warning
902, [Activation Delay seconds: 0-99], #
Pressing the egress button will
sound a warning and grant access
Single press, warning,
and alarm
903, [Activation Delay seconds: 0-99], #
Pressing the egress button will
sound a warning, activate alarm,
and grant access
Hold press, no warning
904, [Hold duration in seconds: 0-99], #
Holding the egress button for the
defined duration will silently grant
access
Hold press, warning
905, [Hold duration in seconds: 0-99], #
Holding the egress button for the
defined duration will sound a
warning and grant access
Hold press, warning, and
alarm
906, [Hold duration in seconds: 0-99], #
Holding the egress button for the
defined duration will sound a
warning, activate alarm, and grant
access
Wiegand
Stand-alone Mode
(Default)
940#
Keep this mode if not using
Wiegand
Code Reader Mode
941#
The keypad provides Wiegand Data
Output for all entries but does not
operate the outputs. It solely
becomes a code reader
Master Keypad of Dual
Keypad Mode
942#
The Master Keypad will transfer all
the programmed feature data to the
access controller.
Note: Setting multiple keypads to
master will confuse the system.
Slave Keypad of Dual
Keypad Mode
943#
The Slave Keypad requires data
from the Master Keypad to operate.
Note: Each keypad in Dual Keypad
Mode can have its own individual
set of codes.