DOLKSF1KB

 

Programming and installation manual 
 

INTRODUCTION

 

The DOLKSF1KB is a secure and waterproof keypad with two relay outputs. It can work 
independently as a stand-alone keypad or it can work as an additional controller to create a high-
security dual keypad system. It also has a 34-bit Wiegand data output from the entry of a 
pin/code. 
 

 

 
CONNECTION TERMINALS

 

 

1-2: 12-24V DC (Power Input Terminal) 

 

Connect 12V-24V AC/DC power. The (-) is the common ground. 

 

3-5: OUTPUT (Output Relay 1) 

 

N.C. (Normally closed) 

 

Use N.C. for equipment that requires a constant flow of electricity to function 
properly. Ex. Magnetic locks, receivers, etc. 

 

COM (Common ground) 

 

N.O. (Normally open) 

 

Use N.O. for equipment that requires a temporary surge of electricity to activate. 
Ex. Electric door locks, automated gates, etc. 

 

6: EG IN ( Egress Input) 

 

The optional EG. IN terminal is (-) and commonly connected to buttons. Buttons that are 
connected to EG. IN will grant access when pressed. 

 

7: DU OUT (Duress Output) 

 

When a Duress Code is entered, the DU OUT will switch to ground. Ex. It may be used 
to turn on a light, camera, or buzzer. It may also be used to trigger an alarm for a 
security system. 

 

8-9: TAMPER N.C. (Tamper Switch Normally Closed Contact) 

Содержание dolksf1kb

Страница 1: ...USER MANUAL Single Gang Flush Mount Keypad DOLKSF1KB V 3 6 18...

Страница 2: ......

Страница 3: ...ed Use N C for equipment that requires a constant flow of electricity to function properly Ex Magnetic locks receivers etc COM Common ground N O Normally open Use N O for equipment that requires a tem...

Страница 4: ...warning if the door is left open for longer than the programmed time Interlock Control The Interlock Control is a two keypad two door feature and it will disable the other keypad as long as its door...

Страница 5: ...RECT ACCESS PROGRAMMING WITH CODE 8080 By pressing the egress button and entering code 8080 during the 1 minute booting time the keypad will bypass the Master Code to enter Programming Mode Take these...

Страница 6: ...4 8 digit Access Code Set 4 8 digit code for general access Each unique 4 8 digit code will require a new user number Important Note It is important to document your user numbers because users can be...

Страница 7: ...tor Code 4 Output number 1 2 or 3 User number 01 50 Delete the user s Duress Code Clear all Visitor Codes 4 Output number 1 2 or 3 0999 Clear all Access Codes Lock Settings Set door unlock timer 5 Out...

Страница 8: ...code will be required but all codes may vary in digit length Blinking Yellow LED Settings Blinking Yellow LED On 731 The amber LED will blink every 2 seconds during functionality Blinking Yellow LED O...

Страница 9: ...cess Hold press warning 905 Hold duration in seconds 0 99 Holding the egress button for the defined duration will sound a warning and grant access Hold press warning and alarm 906 Hold duration in sec...

Страница 10: ...he lock parallel with the lock power terminals to absorb the back EMF and prevent keypad damage The 1N4004 is not required for AC power To avoid electrostatic discharge from interfering with the keypa...

Страница 11: ...O dry contacts 1A 24VDC Max Output Relay 3 N C N O dry contacts 1A 24VDC Max N O contact only for Door Bell version Tamper Switch N C dry contact 50mA 24VDC Max Dimensions DOLKSF1KB 4 3 4 H X 3 1 8 W...