A-100WP 

SEALED ENVIRONMENT KEYPAD 

 

WIRING & PROGRAMMING INSTRUCTIONS 

WI1496  12/06 

GENERAL DESCRIPTION 

The A-100WP is a self-contained access control keypad de-
signed for the harshest outdoor environments.  Its heavy 
stainless steel enclosure and metal keypad buttons also 
make it extremely vandal resistant.  The A-100WP operates 
up to three outputs (two relays and 1 open-collector transis-
tor) and can be used to trigger a door strike, an electromag-
netic door lock, or any other relay-activated device.  Pro-
gramming is performed manually at the keypad, allowing up 
to 150 individual Users, each with their unique User Codes.  
The A-100 Series includes the indoor stainless steel A-100 
(see WI1495) and the waterproof A-100IMWP (see WI1497) 
mullion keypad with illuminated keys. 

 

In a typical application, the A-100WP will energize one or 
both relays upon the keypad entry of a valid User Code.  
Outputs 1 and 2 are two relays of the three contact Form C 
type, and Output 3 is an open collector transistor (terminal 
labeled "OC") that switches "on" (closes with the ground ter-
minal) when energized.  The length of time the outputs are 
energized (their "activation duration") can be programmed to 
between 1 and 99 seconds.  A Request-to-Exit button will 
momentarily short Output 1 by wiring terminals M and P1 
using a normally-open momentary-close switch.   

 

To program the keypad functions you must first perform the 
initial startup procedure, then enter 

Program Mode 

by press-

ing the Master Code at the keypad.  Once in Program Mode, 
all system functions can be accessed and programmed.  Exit 
Program Mode to put the keypad (with its new programming) 
into use. 

 

A-100WP Wiring Table  

Terminal Markings 

Description 

+ 12V or 24V AC/DC Input 

– 

– Ground 

Request to Exit Input 

P1 

Request to Exit Input 

NO 

Relay 1 Normally Open 

C1 

Relay 1 Common 

NC 

Relay 1 Normally Closed  

NO 

Relay 2 Normally Open 

C2 

Relay 2 Common 

 

NC 

Relay 2 Normally Closed 

 

OC 

Open Collector Output 

S1 

Tamper SW Output 

S2 

Tamper SW Output 

12V 

or 24

V AC/

DC I

nput

 

– Grou

nd

 

Common Relay 

R

eq

ue

st to

 Exi

t In

pu

R

eq

ue

st to

 Exi

t In

pu

No

rm

ally

 Op

en

 Re

la

y 1

 

Common Relay 

Normally Closed Relay 1

 

No

rm

ally

 Op

en

 Re

la

y 2

 

Normally Closed Relay 2

 

NC  NO 

NO  C1 

C2 

P1 

– 

NC 

A-100WP Keypad 

SPECIFICATIONS 

12 to 24VDC (polarized) or 12 to 24VAC voltage input  

Output 1:  5A/250VAC relay 

Output 2:  5A/250VAC relay 

Output 3:  250mA open collector  

Capacity of 150 User Codes of 3 to 6 digits 

Output activation duration programmable from 01-99 
seconds (program "00" to select "toggle" mode) 

All programming stored in non-volatile EEPROM memory 

12 Braille keypad keys 

Orange LED Keypress feedback 

Output #1 relay activation duration programmable per 
user code 

Tamper switch output terminals (S1 - S2) on PCB 

Sounder "beeps" can be activated or deactivated for 
user code entries 

Operating Temperature:    -13°F to 131°F 

                                                 -25°C to +55°C 

Dimensions (WxHxD):   4" x 4¾" x 2" 

                                              10.1cm x 12cm x 5cm 

Operating Voltage:      12VDC to 28VDC 

                                          10VAC to 26 VAC 

Maximum Current Draw: 

12VDC:  15mA (Standby)     54mA (Active) 
24VDC:  22mA (Standby)     67mA (Active) 
12VAC:  32mA (Standby)   108mA (Active) 
24VAC:  54mA (Standby)   129mA (Active) 

S2  S1 

OC 

Open Collector Output 

Tam
per SW 

Output 

Ta

m

pe

r SW
 O

utp

ut 

345 Bayview Avenue 

Amityville, New York 11701 

For Sales and Repairs 1-800-ALA-LOCK 

For Technical Service 1-800-645-9440 

 

 

Publicly traded on NASDAQ   Symbol: NSSC 

© ALARM LOCK 2006 

Содержание A-100WP

Страница 1: ...rammed Exit Program Mode to put the keypad with its new programming into use A 100WP Wiring Table Terminal Markings Description 12V or 24V AC DC Input Ground M Request to Exit Input P1 Request to Exit Input NO Relay 1 Normally Open C1 Relay 1 Common NC Relay 1 Normally Closed NO Relay 2 Normally Open C2 Relay 2 Common NC Relay 2 Normally Closed OC Open Collector Output S1 Tamper SW Output S2 Tampe...

Страница 2: ...4 is basically a se cret passcode that allows you to enter Program Mode But since all keypads leave the factory with this same Master Code the factory Master Code is therefore not very secret and should be changed to your own per sonal Master Code This way only YOU can enter Pro gram Mode and make changes to the keypad program ming Change Factory Master Code Although the factory Master Code can be...

Страница 3: ...m Mode to enter Normal Mode as follows Exit Program Mode Press Note The audible sounder and visual LED indicators are displayed in the text below as follows O2 Orange LED lights and sounder beeps twice G1 Green LED lights and sounder beeps once R2 Red LED lights and sounder beeps twice Note Every duration field is a two digit field Master code is strictly reserved for entering Program Mode and can...

Страница 4: ...gits G1 User Number G1 User Code G1 re enter User Code G1 Some examples of the 2 digits field press 12 to activate Outputs 1 and 2 press 23 to activate Outputs 2 and 3 press 13 to activate Outputs 1 and 3 press 02 to activate Output 2 only press 10 to activate Output 1 only etc Note If Function 70 Output 3 Activates on First Keypress is enabled Output 3 cannot be included in the choices offered by...

Страница 5: ...am displays how to control a single door with two keypads When you enter a valid code on Keypad 2 the magnetic lock unlocks directly When you enter a valid code on Keypad 1 the Request to Exit input of keypad 2 is triggered unlocking the door Note Valid user codes must be programmed into both Keypads 1 and 2 WIRING EXAMPLES ONE KEYPAD CONTROLS A DOOR The diagram at right displays basic wiring how ...

Страница 6: ...C G1 newMC G1 32 Add or Edit a User Code Press 32 G1 User Number G1 User Code G1 re enter User Code G1 33 Add or Edit a User Code with Output 1 Duration Press 33 G1 time 01 99 G1 User Number G1 User Code G1 re enter User Code G1 34 Delete User Code Press 34 G1 User Number G1 52 Add or Edit a User Code with Output Activation Press 52 G1 2 digits G1 User Number G1 User Code G1 re enter User Code G1 ...

Страница 7: ...7 MOUNTING TEMPLATE The A 100WP is designed to be installed in its stainless rugged mounting fixture The fixture is 4 wide and 4 tall ...

Страница 8: ...r authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the produc...

Отзывы: