background image

DOLKPL1KB • DOLKPS1KB 

DOLKSF1KB

 

USER MANUAL

1] 

Connection Terminals

2] 

Basic Wiring Example

3] 

Quick Start Guide

4] 

Programming Guide

5] 

Specifications

VIDEO

INSTRUCTIONAL

Содержание dolkpl1kb

Страница 1: ...DOLKPL1KB DOLKPS1KB DOLKSF1KB USER MANUAL 1 Connection Terminals 2 Basic Wiring Example 3 Quick Start Guide 4 Programming Guide 5 Specifications VIDEO INSTRUCTIONAL...

Страница 2: ...ently as a stand alone keypad 1 2 12 24V DC Power Input Terminal 3 8 OUTPUT 1 and OUTPUT 2 Output Relay 1 and 2 N C Normally closed COM Common ground N O Normally open 9 EG IN Egress Input The optiona...

Страница 3: ...ignal lasts as long as programmed Entering an output 1 code will deactivate the warning signal Open Door Warning The door will signal a warning if the door is left open for longer than the programmed...

Страница 4: ...e lock parallel with the lock power terminals to absorb the back EMF and prevent keypad damage The 1N4004 is not required for AC power To avoid electrostatic discharge from interfering with the keypad...

Страница 5: ...shes 5 Power up delay Continuous Beeps Continuous Flashes 6 Output relay activation 1 second Beep 7 Standby 1 flash every second 8 System refreshing Quick flashes for 2 5 minutes 9 Pin already stored...

Страница 6: ...ing either push and hold down the egress button that has been installed or bridge a wire from the egress in terminal 9 to the negative ground power terminal 15 3 While you are either pushing the butto...

Страница 7: ...equire a new user number Note It is important to docu ment your user numbers because users can be de leted and reassigned new codes for access Delete Access Codes Output 1 2 3 Output Number 05 1 2 or...

Страница 8: ...odes the keypad is dis abled for 60 seconds Duress safety setting 60 2 After 10 successive false codes Duress is activated Entering an Access Code Authorization Code will disable the Duress Output Ext...

Страница 9: ...ber LED will blink every 2 seconds during functionality Operating Voltage 12V 24V DC Auto adjusting Operating Current 40mA quiescent to 100mA three relays active Operation Temperature 4 F to 158 F Env...

Страница 10: ...100mA sink Max for the following outputs a Duress b Alarm c Key Active d Output 3 Door Bell version only e Inter lock Output Contact Ratings Output Relay 1 N C N O dry contacts 5A 24VDC Max Output Rel...

Страница 11: ...CULAR PURPOSE BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS EXPRESS OR IMPLIED WITH REGARD TO THE GOODS AND ACCEPTS THEM AS IS WHERE IS TRANSMITTER SOLUTIONS SELLS THE GOODS T...

Страница 12: ...7380 S Eastern Ave Suite 124 320 Las Vegas NV 89123 866 975 0101 866 975 0404 fax www transmittersolutions com...