Visual LED Indicators 

LED 

In Normal Mode 

In Program Mode 

Red 

Remains lit while waiting for a 

keypress 

Confirms errors 

Blinks when editing an existing User Number 

Orange 

Flashes to confirm keypress 

Steady On to confirm in Program Mode.  

Flashes to confirm keypress 

Green  Confirms activation of Outputs, mem-

ory reset and Master Code reset 

Confirms valid data or empty User Number 

Audible Sounder Indicators 

Beep(s) 

In Normal Mode 

In Program Mode 

1 short 

Unit power up and when a key is 

pressed 

Valid data confirmation 

1 long 

Relay activation following a valid 

User Code 

Data recorded 

4 short 

Data error 

Data Error 

2 short 

Enter Program Mode 

Exit Program Mode 

TWO KEYPADS CONTROL ONE DOOR 

The below diagram displays how to control a single door with two keypads.  When you enter a valid code on Keypad 
2, the magnetic lock unlocks directly.  When you enter a valid code on Keypad 1, the Request-to-Exit input of keypad 
2 is triggered, unlocking the door.  

Note:  

Valid user codes must be programmed into both Keypads 1 and 2. 

WIRING EXAMPLES

 

ONE KEYPAD CONTROLS A DOOR 

The diagram at right displays basic wiring--
how to control a single door with one keypad.  
When you enter a valid code on Keypad 1, the 
magnetic lock unlocks directly.  This wiring is 
"Fail Secure" which means that if power is 
lost, the door will remain locked. 

NC  NO 

NO  C1 

C2 

P1 

– 

NC 

S2  S1 

OC 

A-100WP 

Electromagnetic 
Door Lock  
(Fail Secure) 

N/O  
Request-
to-Exit 
Button 

12-24 VDC /

VAC Power 

NC  NO 

NO  C1 

C2 

P1 

– 

NC 

S2  S1 

OC 

A-100WP 

12-24 VDC /

VAC Power 

NC  NO 

NO  C1 

C2 

P1 

– 

NC 

S2  S1 

OC 

A-100WP 

Electromagnetic 
Door Lock  
(Fail Secure) 

12-24 VDC /

VAC Power 

Содержание A-100WP

Страница 1: ...rammed Exit Program Mode to put the keypad with its new programming into use A 100WP Wiring Table Terminal Markings Description 12V or 24V AC DC Input Ground M Request to Exit Input P1 Request to Exit Input NO Relay 1 Normally Open C1 Relay 1 Common NC Relay 1 Normally Closed NO Relay 2 Normally Open C2 Relay 2 Common NC Relay 2 Normally Closed OC Open Collector Output S1 Tamper SW Output S2 Tampe...

Страница 2: ...4 is basically a se cret passcode that allows you to enter Program Mode But since all keypads leave the factory with this same Master Code the factory Master Code is therefore not very secret and should be changed to your own per sonal Master Code This way only YOU can enter Pro gram Mode and make changes to the keypad program ming Change Factory Master Code Although the factory Master Code can be...

Страница 3: ...m Mode to enter Normal Mode as follows Exit Program Mode Press Note The audible sounder and visual LED indicators are displayed in the text below as follows O2 Orange LED lights and sounder beeps twice G1 Green LED lights and sounder beeps once R2 Red LED lights and sounder beeps twice Note Every duration field is a two digit field Master code is strictly reserved for entering Program Mode and can...

Страница 4: ...gits G1 User Number G1 User Code G1 re enter User Code G1 Some examples of the 2 digits field press 12 to activate Outputs 1 and 2 press 23 to activate Outputs 2 and 3 press 13 to activate Outputs 1 and 3 press 02 to activate Output 2 only press 10 to activate Output 1 only etc Note If Function 70 Output 3 Activates on First Keypress is enabled Output 3 cannot be included in the choices offered by...

Страница 5: ...am displays how to control a single door with two keypads When you enter a valid code on Keypad 2 the magnetic lock unlocks directly When you enter a valid code on Keypad 1 the Request to Exit input of keypad 2 is triggered unlocking the door Note Valid user codes must be programmed into both Keypads 1 and 2 WIRING EXAMPLES ONE KEYPAD CONTROLS A DOOR The diagram at right displays basic wiring how ...

Страница 6: ...C G1 newMC G1 32 Add or Edit a User Code Press 32 G1 User Number G1 User Code G1 re enter User Code G1 33 Add or Edit a User Code with Output 1 Duration Press 33 G1 time 01 99 G1 User Number G1 User Code G1 re enter User Code G1 34 Delete User Code Press 34 G1 User Number G1 52 Add or Edit a User Code with Output Activation Press 52 G1 2 digits G1 User Number G1 User Code G1 re enter User Code G1 ...

Страница 7: ...7 MOUNTING TEMPLATE The A 100WP is designed to be installed in its stainless rugged mounting fixture The fixture is 4 wide and 4 tall ...

Страница 8: ...r authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the produc...

Отзывы: