User manual DPC Touch V2
DOC.60352-11/20
60
Input signal is not
received
Input signals should be between 20 and 30V in order
to be detected by the controller. Check if signal is
detected in Other settings, real time monitoring.
Output signal is not
sent
Max current capacity of outputs is 100 mA per output
and total of 500mA for all outputs. To check wiring,
force output signal in Other settings, real time
monitoring. Outputs are optically isolated.
Image message is not
displayed on the
screen
Check image size and format. Images have to be in
JPEG format with following size: 800x480 px.
The job is locked in an
endless loop
Make sure that a job contains at least one Fastening
or one Logical input step. Otherwise the job will be
stuck in automatic loop.
Rapidly press the HOME icon to stop the job and
then correct it.
Error: “Fastening time
is too short/long”
Check fastening time control limits in operating
settings. Check saved min and max fastening time in
corresponding fastening step. Reprogram or modify
manually if needed. To deactivate the tightening time
control, set min & max fastening time at 0 in the
fastening step programming.
NOTE: control limits in operating settings are only
applied to newly created jobs.
Error: “Trigger
released before torque
up”
Check min threshold for trigger release control in
operating settings (screen 3 of 4). If start trigger is
released after the min threshold, the error is
displayed. To disable trigger release control, set the
threshold to 0 or to 9999.