User manual DPC Touch V2
DOC.60352-11/20
23
3.3.4 Operating - Management of NG tightenings
Parameters
Description
Range
Default
Value
Numbers of
retightenings
on a position
Maximum number of attempts to
rework a NG fastening. If the maximum
number of attempts is reached the
current position can be skipped or
Job/Step can be reset according to
parameters selected.
NOTE: this parameter is not effective in
non-sequential assembly mode.
0 - 10
1
Skip NG
tightening
Allows automatic skipping of a NG
tightening if rework is not allowed or if
rework wasn’t successful.
ON/OFF
OFF
Fastening NG
signal if
position
skipped
If turned ON, Fastening NG signal will
be provided when a position is skipped
automatically, by Skip button on the
operating screen or by external input. If
turned OFF, Fastening OK signal will be
provided.
ON/OFF
ON
Auto reset
delay, ms
Alarm can be reset automatically after
the specified delay. If delay is equal to 0
than reset has to be done manually or
by external input.
0 - 9999
3000