User manual DPC Touch V2
DOC.60352-11/20
46
Example:
For a screw position saved as follow CH1:
300
& CH2:
500
, and for an
OK zone
defined with
80
pts on CH1 and
100
pts on CH2, and a
Tolerance zone
defined with
150
pts on CH1 and
200
pts on CH2:
Screw (Location CH1: 300 / CH2: 500)
Encoder position CH1
Encoder position CH2
OK zone on CH2
Tolerance area on CH2
Tolerance area on CH1
OK zone on CH1
100
200
80
150
OK
To
ler
an
ce
zo
ne
Outside area
In the
OK zone
, tool is enabled.
In this example, this OK zone contains all positions on CH1 between 220 and
380 (
300
+/-
80
) and on CH2 between 400 and 600 (
500
+/-
100
).
In the
tolerance zone
, tool is disabled. If the option «Temporary position loss
time» is activated (see paragraph 3.3.3.), the tool can finish its cycle even if it
enter in the tolerance zone during the fastening.
In this example, the tolerance zone contains all positions on CH1 between 150
and 450 (
300
+/-
150
) and on CH2 between 300 and 700 (
500
+/-
200
).
Out of those zones, tool is disable.
Smart tolerance:
the OK zone can be defined using this automatic function
(refer to paragraph 4.4.6). Must be used after the position is defined.