User manual DPC Touch V2
DOC.60352-11/20
47
Information
The actual shape of the tolerance zones varies. They depend on the
geometry of the arm used. To avoid overlapping tolerance zones,
keep tolerance values as low as possible.
The step name can be changed via the numeric keypad by clicking directly on
the current name. There must already be a position created in this step for the
new step name to be saved.
On the right of the screen, choose to activate the non-sequential option to
leave the operator free to tighten screws in any order. Otherwise, the screws
will be to be tightened according to the registration order.
On the right of the screen, the screwdriving time control panel displays the
screwdriving times and the min/max limits.
The minimum/maximum values are calculated according to the percentage
defined in the screwdriving parameters.
Finally, the position management table contains the following information:
Tightening Job
Preset number to be selected for the current tightening
position via 24V outputs (direct or binary logic) if supported
by the tool.
Retightening
job
Similar to the Tightening job but it is used only for rework
operation and it is automatically selected after NG
tightening (if retightening is enabled in operating settings)