39
Manual for PC Connection_PR17.fm
Operation when parameter is abbreviated
AT+CGDCONT=
Clears all <cid> settings. Resets <cid>=1, 3 or 4 setting to default value.
AT+CGDCONT=<cid>
Clears specified <cid> setting. Resets <cid>=1, 3 or 4 setting to default value.
AT+CGDCONT=?
Displays list of values that can be set.
AT+CGDCONT?
Displays current settings.
■
Command name: +CGEQMIN=[parameter]
Overview
Registers criterion determining whether to permit QoS (Quality of Service) sent from the network when
establishing PPP packet communication.
Not stored in FOMA terminal’s memory with AT&W commands. Not reset with AT&F or ATZ commands.
Syntax
AT+CGEQMIN=[<cid> [,, <Maximum bitrate UL> [, <Maximum bitrate DL>[,,,,<Maximum SDU size>]]]]
o
Parameter description
<cid>
: 1 to 10
<Maximum bitrate UL>
: None (initial setting) or 5760
<Maximum bitrate DL>
: None (initial setting) or 7232
<Maximum SDU size>
When <PDP_type> is PPP : 10 (initial setting) to 1500 or 1502
When <PDP_type> is IP
: 10 (initial setting) to 1500
<cid> is a number for managing hosts (APNs) used for packet communication, registered in the FOMA
terminal. [Maximum bitrate UL] and [Maximum bitrate DL] set the maximum uplink and downlink transmission
speed (kbps) between the FOMA terminal and base station. When set to [None] (default setting), all speeds
are permitted. However, when set to “5760” and “7232”, connections established under these speeds are not
permitted, so packet communication connection may not be established. Set the maximum permitting SDU
size for [Maximum SDU size]. Note that when “10 (initial setting) to 1500 or 1502” is set, connections
established under these values are not permitted, and packet communication may not be connected. Note
that connections established under “70” are not available.
Execution examples
Setting (1) is the initial setting for all cid.
(1) Command permitting all uplink/downlink speeds (for <cid>=5)
AT+CGEQMIN=5
o
OK
(2) Command permitting uplink speeds of 5,760 kbps, downlink speeds of 7,232 kbps, and maximum permitting
SDU size 1500 (for <cid=6>)
AT+CGEQMIN=6,,5760,7232,,,,1500
o
OK
(3) Command permitting uplink speeds of 5,760 kbps and all downlink speeds (for <cid>=7)
AT+CGEQMIN=7,,5760
o
OK
(4) Command permitting all uplink speeds and downlink speeds of 7,232 kbps (for <cid>=8)
AT+CGEQMIN=8,,,7232
o
OK
Operation when parameter is abbreviated
AT+CGEQMIN=
Clears all <cid> settings.
AT+CGEQMIN=<cid>
Returns specified <cid> setting to default setting.
AT+CGEQMIN=?
Displays list of values that can be set.
AT+CGEQMIN?
Displays current settings.
Manual for PC Connection_PR17.fm 39 ページ 2012年11月22日 木曜日 午前8時50分