7. GPO ACTIONS WEB PAGE

 

 

 

 

GPO Label 

Enter any 15 characters or symbols.  For convenience 
only.  Used in Event Action Table 

User Defined 
ON State 

RELAY OPEN

:  The relay is OPEN when the GPO is ON.  The relay is CLOSED when the 

GPO is OFF. 

RELAY CLOSED

:  The relay is CLOSED when the GPO is ON.  The relay is OPEN when the 

GPO is OFF (Factory Default). 

USP3 User Manual

 

Page 11 of 46 
 
 

 

Содержание USP3-16

Страница 1: ...SWITCH PANEL USP3 8 USP3 16 USP3 8D USP3 S24 USP3 Shotbox User Manual 19770 Bahama St Northridge CA 91324 V 818 898 3380 F 818 898 3360 sales dnfcontrols com www dnfcontrols com USP3 User Manual Page...

Страница 2: ...18 13 AHSC RECEIVE EVENT 19 14 HTTP GET POST ACTIONS 21 15 SNMP RX TX ACTIONS 23 16 MEM CONFIGURATION 25 17 EVENT ACTION TABLE 26 18 TALLY ASSIGNMENT 30 19 EXAMPLES RECEIVE PATTERN MATCHING 32 20 EXA...

Страница 3: ...5 Updated to include new web pages 1 02 10 16 15 Added TALLY ASSIGNMENT web page 1 03 08 09 16 Added MEM SNMP Serial and Toggle Actions with MEM pages 1 05 07 18 17 Added HTTP GET POST ACTIONS and VIE...

Страница 4: ...erial Ethernet messages Control Flex Control Network devices Tally them And more Tactile Fast Easy Dependable CONTROL Getting Started 1 Go to Installation Section to install the USP3 2 Go to System Co...

Страница 5: ...e to access the desired configuration web pages All configuration settings are saved in non volatile memory in the USP3 Settings are retained when power is removed Settings may be uploaded to a comput...

Страница 6: ...N WEB PAGE P1 Software Upgrade Use this link to install the P1 upgrade file provided by DNF Controls Web Upgrade Use this link to install the Web pages upgrade file provided by DNF Controls USP3 User...

Страница 7: ...with redundant mode enabled upon powerup If set to Disabled the USP will boot up with redundant mode disabled upon powerup Key Mode on Powerup Use this dropdown to set the Key Mode on Powerup If set t...

Страница 8: ...page monitors all incoming data from the selected remote device Use the Refresh link to view incoming data as it is received Use the Clear Log link to clear the log data NOTE View Received Data page d...

Страница 9: ...6 GPI EVENTS WEB PAGE GPI Label Enter any 15 characters or symbols For convenience only Used in Event Action Table USP3 User Manual Page 9 of 46...

Страница 10: ...HED The GPI turns ON and stays ON The GPI turns OFF and stays OFF MOMENTARY The GPI turns ON for a short time and then turns OFF and stays OFF This pattern repeats every time the GPI become active Deb...

Страница 11: ...ce only Used in Event Action Table User Defined ON State RELAY OPEN The relay is OPEN when the GPO is ON The relay is CLOSED when the GPO is OFF RELAY CLOSED The relay is CLOSED when the GPO is ON The...

Страница 12: ...viously OFF The GPO turns OFF if it was previously ON Momentary ON Time For MOMENTARY operating mode only ON duration for Momentary GPO Drop down menu settable from 0 01 sec to 2 0 sec Group Radio Gro...

Страница 13: ...ontrols USP s AIB s EB 4X s and EG 4 s GTP 32 DC20 Use to connect to DNF Controls GTP 32 and DC20 21 PKM Use to connect to PC for Keymapper functionality USP3 API Use to connect to a 3rd party for dir...

Страница 14: ...s not provide guaranteed delivery UDP Attempts provides more than one transmit attempt to deliver the message IP Address URL Enter the IP address or URL for remote device to be controlled or monitored...

Страница 15: ...key is pressed the assigned Key Mapper List entry is transmitted to the Panel Key Mapper application pkm exe running on the Microsoft Windows based remote device Label Enter any 32 characters or symbo...

Страница 16: ...ess of this USP3 The entered Event Label must exactly match the event label in the Event Notification Table User Register Value For use with UR_ event labels only Enter a value 1 to 255 When the recei...

Страница 17: ...GURATION Port Configuration RS232 DTE or RS422 Controller Baud Rate 300 1200 2400 4800 9600 19200 38400 Parity None Odd Even Data Bits Fixed at 8 Stop Bits Fixed at 1 Start Bits Fixed at 1 USP3 User M...

Страница 18: ...to add a WAIT time 001 999 milliseconds Three numbers must follow WT The characters preceding WT are sent immediately The characters after WTttt are sent after the wait time expires More than one WT c...

Страница 19: ...13 AHSC RECEIVE EVENT Event Label Enter any 32 characters This label is for convenience only and is used in the Event Action Table USP3 User Manual Page 19 of 46...

Страница 20: ...X character Enter XX to ignore the received value Use yyyyyyyy to match an exact bit pattern y values are 0 1 or X don t care For example enter 0XXX1XXX to match bit7 0 and bit3 1 Bit0 is on the far r...

Страница 21: ...T GET Requests data from a specified resource POST Submits data to be processed to a specified resource Action Label Enter any 32 characters This label is used in the Event Action Table Mode Use the d...

Страница 22: ...pe Options available Text plain Text HTML Application XML Application JSON Application x www form urlencoded Data Enter the data of the HTTP POST or GET Remainder of page is blank USP3 User Manual Pag...

Страница 23: ...any 32 characters This label is for convenience only and is used in the Event Action Table Community Community string is 1 32 characters in length Typical value is public Command SET GET GET RESPONSE...

Страница 24: ...88 Maximum entered decimal value is 99999999 Value Type OID Value OID Value Type Integer Enter decimal value 0 999999 for OID value OctetInteger Enter decimal value 0 999999 for OID value Octet String...

Страница 25: ...eb page to control LCD Key text and color In the Event Action Table an Event IN can turn ON turn OFF or TOGGLE the state of a MEM Also a MEM can be used as an Event IN to trigger an ON or OFF ACTION F...

Страница 26: ...ssignment web page and change the Device Type or Connection Type for the Remote Device There are 16 Sequence Timers Use each Sequence Timer event number in multiple lines as the Event Type to create a...

Страница 27: ...e Event Action table After the timer has expired and its ON ACTION executed the timer automatically restarts for the time period setup in the Event Action table Remote AHSC Receive Event A successful...

Страница 28: ...e Redundant Mode Main Backup Select MAIN Select BACKUP Toggle between MAIN BACKUP Restart Timer Restarts the currently selected timer in the Event Action Table Remote AHSC Transmit Action Transmit the...

Страница 29: ...Backup Select MAIN Select BACKUP Toggle between MAIN BACKUP Restart Timer Restarts the currently selected timer in the Event Action Table Remote AHSC Transmit Action Transmit the selected AHSC Action...

Страница 30: ...when key is pressed Tally is OFF when key is released Follow GPI Tally is ON when GPI is ON Tally is OFF when GPI is OFF Follow GPO Tally is ON when GPO is ON Tally is OFF when GPO is OFF Follow ENAB...

Страница 31: ...ue UR1Tally is ON when the received User Register value matches the UR1 value entry UR2 through UR4 Tally is ON when the received User Register value matches the UR1 through UR4 value entry respective...

Страница 32: ...irst third and fourth characters are correct All four received character patterns are a successful pattern match A XX C D 1234ABCDEFG 1234A5CDEFG 4AKCDE Successful pattern matches A XX C D ACD No patt...

Страница 33: ...splay only Notes 0XXX1XXX Bit7 0 Bit3 1 All other bits are Don t care 01011000 Bit 7 is immediately after the Bit 0 is on the far right A pattern match occurs when Bit 7 0 or Bit3 1 Only one of the bi...

Страница 34: ...nd character must be B No pattern match AB CB DB ZB The first character can be any character except A The second character must be B Successful pattern match AB CD The first character can be any chara...

Страница 35: ...ry in the Event Action Table When the last Sequence action executes the sequence will automatically turn off and stop executing If the last Sequence action is Sequence Start the sequence will loop unt...

Страница 36: ...ess ON action will FLIP FLOP the action of two GPO s The selected MEM that is being toggled will need to be setup in following manner to trigger the FLIP FLOP action ON ACTION TURN ON GPO_1 TURN OFF G...

Страница 37: ...he MEM s associated with the Radio Group MEM ON must be selected as the ON action for the Radio Group functionality to work properly Assign each MEM to a specific USP3 Key in the Tally Assignment page...

Страница 38: ...n the MEM Configuration page assign a MEM to each GPO that you will be using for your Radio Group Under the Radio Group Dropdown assign all MEM s to the same radio group RG1 RG5 A source event GPI Key...

Страница 39: ...Assignment page When a Source Event triggers on the USP3 the MEM tied to this source event will turn ON This MEM ON action will cause its Key tally to turn ON all other Key tallies in the same Radio...

Страница 40: ...d 10 seconds to reset IP address to 192 168 10 217 and configuration to factory default SERIAL CONNECTOR Pin RS232 DTE RS422 Controller RS422 Device 1 N C Frame Ground Frame Ground 2 RxD Receive A Tra...

Страница 41: ...earby V pin Connect GPI to Ground to turn on GPI Pin Description Pin Description 1 Ground 14 GPI 8 2 GPI 8 15 V 3 V 16 GPI 7 4 GPI 7 17 GPI 6 5 GPI 6 18 V 6 V 19 GPI 5 7 GPI 5 20 GPI 4 8 GPI 4 21 V 9...

Страница 42: ...8 Common 15 Common Bus 3 Common Bus 16 GPO 7 N O 4 GPO 7 Common 17 GPO 6 N O 5 GPO 6 Common 18 Common Bus 6 Common Bus 19 GPO 5 N O 7 GPO 5 Common 20 GPO 4 N O 8 GPO 4 Common 21 Common Bus 9 Common B...

Страница 43: ...25 USP S24 Key Layout Rear Panel USP3 User Manual Page 43 of 46...

Страница 44: ...26 USP3 8D Key Layout Rear Panel USP3 User Manual Page 44 of 46...

Страница 45: ...SHOTBOX Key Layout Rear Panel 1 1 3 2 5 1 4 1 1 3 2 5 1 4 1 1 3 2 5 1 4 1 1 3 2 5 1 4 1 6 GPI 1 8 GPI 9 16 GPO 1 8 GPO 9 16 Serial ETHERNET S1 Reset POWER 2 POWER 1 Rear View USP3 User Manual Page 45...

Страница 46: ...lace the defective unit DNF Controls will return the unit prepaid to the customer The method of shipment is at the discretion of DNF Controls principally UPS Ground for shipments within the United Sta...

Отзывы: