7000 Series Keypad Installation Sheet 

Digital Monitoring Products

11

Specifications

Operating Voltage 

12 VDC Nominal

Dimensions 

7” W x 5.25” H x 0.5” D

Compatibility

The 7000 Series keypads are compatible with 

the following Command Processor™ panels:

XRSuper6/XR20/XR40
XR200/XR200-485/XR2400F
XR500 Series/XR2500F

Listings and Approvals

Underwriters Laboratories (UL) Listed
FCC Part 15
RFID Reader FCC ID: CCKPC0086

Accessories

Backboxes

695 or 696 4” square mounting box

777 protective keypad cover

777S keypad cover spacer

Keypad Wiring Harness

300 4-wire harness

300-5 5-wire harness

300-12 12-wire harness

300-512 12-wire harness, 5 ft. long

Proximity Credentials

1306 HID Prox Patch™

1306PW HID Prox Patch™

1326 HID ProxCard II® Card

1346 HID ProxKey II® Access Device

1351 HID ProxPass®

1386 HID ISOProx II® Card

1410 DMP Proximity Card  

1415 DMP Proximity PVC Photobadge 

1420 DMP Proximity Key Fob 

Keypad Specifications

MODEL NORM/STANDBY 

CURRENT

ALARM 

CURRENT

4-ZONES

INTERNAL 

PROX READER

WIEGAND 

INPUT

INTERNAL FORM C 

DOOR STRIKE RELAY

7060

72mA

87mA

7063

85mA

100mA

X

7070

72mA + 1.6mA 

per active zone

87mA + 2mA 

per active zone

X

7073

85mA + 1.6mA 

per active zone

100mA + 2mA 

per active zone

X

X

X

X

FCC Information

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 

(1) This device may not cause harmful interference, and 

(2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications made by the user and not expressly approved by the party responsible for compliance could 

void the user’s authority to operate the equipment.

NOTE

:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 

to part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful 

interference in a residential installation.  This equipment generates, uses and can radiate radio frequency 

energy and, if not installed and used in accordance with the instructions, may cause harmful interference 

to radio communications.  However, there is no guarantee that interference will not occur in a particular 

installation.  If this equipment does cause harmful interference to radio or television reception, which 

can be determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures:
-  Reorient or relocate the receiving antenna.
-  Increase the separation between the equipment and receiver.
-  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-  Consult the dealer or an experienced radio/TV technician for help.

Содержание Thinline 7060

Страница 1: ... switch box DMP 695 and 696 backbox or a flat surface Figure 1 shows the keypad housing mounting hole locations Removing the Base The keypad housing is made up of two parts the front which contains the circuit board keyboard components and the base To remove the base insert a flat screwdriver into one of the openings on the bottom and twist the screwdriver while pulling the halves apart Repeat wit...

Страница 2: ...nel output you can provide additional current by adding a Model 505 12 auxiliary power supply Connect all keypad black ground wires to the power supply negative terminal Run a jumper wire from the power supply negative terminal to the panel common ground terminal Connect all keypad power 12 VDC wires to the power supply positive terminal Do NOT connect the power supply positive terminal to any pan...

Страница 3: ...el the keypad door strike relay activates for 5 seconds During this time the access door connected to zone 2 must be opened to start the 40 second entry exit timer and zone Soft Shunt See the timeline shown below Note The 5 second door strike is programmable when the keypad is used on an XR200 485 XR500 Series or XR2500F panel Refer to the XR500 Series Programming Guide LT 0679 or the XR200 485 Pr...

Страница 4: ...on Panic left two Select keys Zone 19 Device Address Emergency non medical center two Select keys Zone 29 Device Address Fire right two Select keys Zone 39 Device Address Figure 5 Panic key label placement 7 0 Panic Keys The 7000 Series keypads also allow the user to initiate a Panic alarm by pressing the 7 and 0 zero keys simultaneously for one half 1 2 second You must enable the 7 0 Panic functi...

Страница 5: ...uble conditions the volume is always at maximum level Use the left Select key to decrease the keypad volume and the right Select key to increase the volume Press the CMD key to display the Model Number MODEL NUMBER 7073 V201 030804 Model Number The LCD displays the keypad model number and the keypad firmware version and date The user cannot change this information in User Options KEYPAD ADDRESS 01...

Страница 6: ...P UNSUP Keypad Mode Configure the keypad for either supervised or unsupervised operation Keypads with zones connected to them must be supervised Supervised keypads cannot share addresses with other keypads Unsupervised keypads can operate with other unsupervised keypads sharing the same address Zones cannot be used on unsupervised keypads To change the current setting press the Select key under SU...

Страница 7: ...resented for arming the Home Sleep Away system After a card is presented HOME SLEEP AWAY displays The keypad waits the programmed number of seconds before automatically selecting AWAY Accessing Keypad Diagnostics If necessary refer to Access the Installer Menu on the previous page KPD KPD OPT DIAG STOP Keypad Diagnostics KPD DIAG The Keypad Diagnostic option allows you to check the display segment...

Страница 8: ...lay present the credential to the reader The keypad works by reading the 4 or 5 digit user code from the data sent by the access control reader For more information refer to Entry Cards in the programming section of this document and the following User s Guide section on adding deleting and changing user codes 7063 and 7073 User s Guide There are three different sections Keypad Arming and Disarmin...

Страница 9: ...are disarmed If the system is disarmed when you present your card once the card is validated all areas are armed in the AWAY mode Keypad Door Strike Area and All Perimeter Door Strike From the Status List present your card to the reader Once the system validates the card the Door Strike relay activates Home Away systems only activate the Door Strike relay when arming and disarming Figure 10 Presen...

Страница 10: ... X FCC Information This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications made by the user and not expressly approved by the party responsible for compliance could...

Отзывы: