Wiring Specifications

When planning a keypad bus installation, keep in mind the following specifications:

1. DMP recommends using 18 or 22-gauge 

unshielded 

wire for all keypad and LX-Bus circuits.  

Do Not

 use 

twisted pair or shielded wire for LX-Bus and keypad bus data circuits.  To maintain auxiliary power integrity 

when using 22-gauge wire do not exceed 500 feet.  When using 18-gauge wire do not exceed 1,000 feet.  

Install an additional power supply to increase the wire length or add devices. 

2. Maximum distance for any one circuit (length of wire) is 2,500 feet regardless of the wire gauge.  This 

distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than 

2,500 feet.  As wire distance from the panel increases, DC voltage on the wire decreases.

3. Maximum number of devices per 2,500 feet circuit is 40.  

Note:

  Each panel allows a specific number of supervised keypads.  Add additional keypads in the 

unsupervised mode.  Refer to the panel installation guide for the specific number of supervised keypads 

allowed.  

4. Maximum voltage drop between the panel (or auxiliary power supply) and any device is 2.0 VDC.  If the 

voltage at any device is less than the required level, add an auxiliary power supply at the end of the circuit.  

When voltage is too low, the devices cannot operate properly.  

Refer to the 710/710F Module Installation Sheet (LT-0310) for more information.  Also see the LX-Bus/Keypad Bus 

Wiring Application Note (LT-2031).    

Additional Power Supply

If the current draw for all keypads exceeds the panel output, you can provide additional current by adding a Model 

505-12 auxiliary power supply.  Connect all keypad black ground wires to the power supply negative terminal.  Run 

a jumper wire from the power supply negative terminal to the panel common ground terminal.  Connect all keypad 

power (+12 VDC) wires to the power supply positive terminal.  Do NOT connect the power supply positive terminal to 

any panel terminal.  Refer to the 504-24 and 505-12 Power Supply Installation Guide (LT-0453) for more information. 

Keypad Bus Monitor

For UL Listed fire protective systems, the 893/893A Module must be installed in the XR500 Series or XR200 control 

panel to monitor the keypad bus and sound an audible trouble whenever the keypad bus fails to operate.  Refer to 

the 893/893A Module Installation Sheet (LT-0135). 

Card Readers

When a proximity credential is presented to an internal or external reader, a beep tone is heard and the Power and 

Armed LEDs blink.  This provides both an audible and visual acknowledgement of the credential read. 

Internal Access Control Reader

The 7063 and 7073 keypads provide a built-in proximity card reader designed to read HID 1300 Series and DMP 1400 

Series proximity credentials.  

Note: For UL Listed access 

control applications, the keypad 

must be installed within the 

protected area.

External Access Control Reader

To accept Wiegand data input 

from HID, DMP, or other external 

card readers, connect a 12 VDC 

external reader to the 7073 

keypad.  Connect the Red and 

Black power wires from the 

reader to the power wires from 

the panel.  These connect in 

parallel with the keypad power 

wires.  Connect the Reader (Data 

1) wire to the White wire on the 

5-wire keypad harness.  Connect 

the Reader (Data 0) wire to the 

Green/White wire on the 5-wire 

keypad harness.

Figure 2: 12 VDC Reader Wiring for 7073 Keypad

Содержание Thinline 7060

Страница 1: ... switch box DMP 695 and 696 backbox or a flat surface Figure 1 shows the keypad housing mounting hole locations Removing the Base The keypad housing is made up of two parts the front which contains the circuit board keyboard components and the base To remove the base insert a flat screwdriver into one of the openings on the bottom and twist the screwdriver while pulling the halves apart Repeat wit...

Страница 2: ...nel output you can provide additional current by adding a Model 505 12 auxiliary power supply Connect all keypad black ground wires to the power supply negative terminal Run a jumper wire from the power supply negative terminal to the panel common ground terminal Connect all keypad power 12 VDC wires to the power supply positive terminal Do NOT connect the power supply positive terminal to any pan...

Страница 3: ...el the keypad door strike relay activates for 5 seconds During this time the access door connected to zone 2 must be opened to start the 40 second entry exit timer and zone Soft Shunt See the timeline shown below Note The 5 second door strike is programmable when the keypad is used on an XR200 485 XR500 Series or XR2500F panel Refer to the XR500 Series Programming Guide LT 0679 or the XR200 485 Pr...

Страница 4: ...on Panic left two Select keys Zone 19 Device Address Emergency non medical center two Select keys Zone 29 Device Address Fire right two Select keys Zone 39 Device Address Figure 5 Panic key label placement 7 0 Panic Keys The 7000 Series keypads also allow the user to initiate a Panic alarm by pressing the 7 and 0 zero keys simultaneously for one half 1 2 second You must enable the 7 0 Panic functi...

Страница 5: ...uble conditions the volume is always at maximum level Use the left Select key to decrease the keypad volume and the right Select key to increase the volume Press the CMD key to display the Model Number MODEL NUMBER 7073 V201 030804 Model Number The LCD displays the keypad model number and the keypad firmware version and date The user cannot change this information in User Options KEYPAD ADDRESS 01...

Страница 6: ...P UNSUP Keypad Mode Configure the keypad for either supervised or unsupervised operation Keypads with zones connected to them must be supervised Supervised keypads cannot share addresses with other keypads Unsupervised keypads can operate with other unsupervised keypads sharing the same address Zones cannot be used on unsupervised keypads To change the current setting press the Select key under SU...

Страница 7: ...resented for arming the Home Sleep Away system After a card is presented HOME SLEEP AWAY displays The keypad waits the programmed number of seconds before automatically selecting AWAY Accessing Keypad Diagnostics If necessary refer to Access the Installer Menu on the previous page KPD KPD OPT DIAG STOP Keypad Diagnostics KPD DIAG The Keypad Diagnostic option allows you to check the display segment...

Страница 8: ...lay present the credential to the reader The keypad works by reading the 4 or 5 digit user code from the data sent by the access control reader For more information refer to Entry Cards in the programming section of this document and the following User s Guide section on adding deleting and changing user codes 7063 and 7073 User s Guide There are three different sections Keypad Arming and Disarmin...

Страница 9: ...are disarmed If the system is disarmed when you present your card once the card is validated all areas are armed in the AWAY mode Keypad Door Strike Area and All Perimeter Door Strike From the Status List present your card to the reader Once the system validates the card the Door Strike relay activates Home Away systems only activate the Door Strike relay when arming and disarming Figure 10 Presen...

Страница 10: ... X FCC Information This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications made by the user and not expressly approved by the party responsible for compliance could...

Отзывы: