Digital Monitoring Products
7000 Series Keypad Installation Sheet
6
7000 Series Keypad Installation Sheet
Digital Monitoring Products
7
ACTIVATE ZONE 3
EXIT:
NO
YES
Zone 3 Exit (7073 only)
Select YES to enable the Request to Exit feature on zone 3 as described earlier in this
document. When shorted, this zone activates the keypad relay. No panel programming
is required.
4 DIGIT ENTRY
CARDS:
NO
YES
Entry Cards
Select YES to enable the 4-Digit Entry Cards function on Home/Away or All/Perimeter
arming systems that require 4-digit user codes. Home/Away operation is available on
the XRSuper6, XR20, XR40, and XR200 Command Processor™ panels.
The table below shows the various compatible panel types and required operating
modes for the arming/disarming feature as well as the appropriate 4 or 5-digit code
configuration for each panel.
Operation
XRSuper6
XR20/
XR40
XR200/
XR2400F
XR200-485/
XR500 Series/XR2500F
Arms H/A
Disarms H/A
4-digit
4-digit
4-digit
4-digit
4-digit
4-digit
N/A
N/A
Arms A/P
Disarms A/P
N/A
4-digit
N/A
4-digit
N/A
5-digit
N/A
N/A
Arms Area(s)
Disarms Area(s)
N/A
N/A
N/A
4-digit*
N/A
5-digit*
N/A
5-digit
* During entry delay only.
ALL?:
NO YES
DELAY:
2
All? No Yes Wait Time (7063 and 7073 only)
Select the number of seconds the keypad should wait when an area system displays
ALL? NO YES during arming/disarming or a HOME/SLEEP/AWAY system waits during
arming only. If NO or YES, or HOME, SLEEP, or AWAY is not manually selected before
the delay expires, the keypad automatically selects the YES or the AWAY key. Select
zero (0) to disable this feature. The delay can be one to nine (1-9) seconds. The
delay also occurs when any credential is presented for arming the Home/Sleep/Away
system. After a card is presented, HOME SLEEP AWAY displays. The keypad waits the
programmed number of seconds before automatically selecting AWAY.
Accessing Keypad Diagnostics
If necessary, refer to Access the Installer Menu on the previous page.
KPD KPD
OPT DIAG
STOP
Keypad Diagnostics (KPD DIAG)
The Keypad Diagnostic option allows you to check the display segments, check the
keyboard backlighting, and test individual keys.
Press the Select key under KPD DIAG. The keypad lights all display segments and
illuminates the keyboard in green. A few seconds later the keypad turns the display off
and illuminates the keyboard in red. The keypad then alternates between these two
states for approximately two minutes. Press COMMAND at any time to continue.
PRESS KEY TO
TEST
Test Individual Keys
The display changes to PRESS KEY TO TEST. This option allows you to test each key on
the keyboard to ensure it is operating properly. Press and hold each key for about two
seconds. The key number being held appears in the display. Verify the correct number
displays before testing the next key.
Z1 OPEN
Z2 OPEN
Z3 OPEN
Z4 OPEN
Zone Test (7070 and 7073 only)
This option allows the keypads to display the current electrical status of the four
protection zones. The status is shown as OPEN, SHRT, or OKAY.
Note
: The Zone Test displays on 7060 and 7063 keypads, but is not operational.
INPUT WIEGAND
Input Wiegand (7063 and 7073 only)
This option tests the internal and external reader input from proximity credentials.
The display shows OKAY each time a good proximity read is received.
Exiting the Installer Options
When done, press the CMD key once to return to the Installer Options screen. Press the Select key under STOP to
exit the Installer Options function.