background image

WCK-2B-CC
WCK-4B-CC

Maximum Ratings: 30VDC, 200mA

Figure A - WCK-2B-CC Keypad wiring

Description

The WCK-2B-CC and WCK-4B-CC window covering
keypads are low-voltage contact closure devices that
interface with various shade controllers through their A/V
terminals. The WCK-2B-CC and WCK-4B-CC keypads
offer Raise and Lower functions of shades that are
controlled by the corresponding shade controllers. These
keypads are low-voltage devices that are designed to fit
into a standard wallbox. The keypads are gangable with
Lutron

®

 Claro

®  

or Nova T

®

 devices. Proper separation of

low-voltage and line voltage devices is required. Keypads
must be connected to shade controller using Class 2/
PELV wiring methods per the National Electrical Code.
Check with your local inspector for the code requirements
and wiring practices in your area. Lutron offers precision
product color matching.

Important Notes

1. Install in accordance with all applicable regulations.

2.

Do not connect high voltage power to device.

Improper wiring can result in personal injury or damage
to the device or to other equipment.

Cleaning Instructions

To clean keypad wipe with a clean damp cloth. 

DO NOT

use any chemical cleaning solutions.

Installation

1. Turn OFF power feeding shade controller.

2. Run the control wire (3 conductor, 22-24 AWG) from

the shade controller to the wallbox for the keypad. See
Figure A.

3.  Strip the insulation 1/2" from the wires.

4.  Using the supplied wire connectors:

For a WCK-2B-CC or the lower section of a
WCK-4B-CC only:

• Connect the YELLOW wire to the wire going to the

Common terminal on the shade controller.

• Connect the GRAY wire to the wire going to the

Down terminal on the shade controller.

     • Connect the VIOLET wire to the wire going to the Up

terminal on the shade controller.

For a WCK-4B-CC upper section only:
• Connect the YELLOW/WHITE wire to the wire going

to the Common terminal on the shade controller.

• Connect the GRAY/WHITE wire to the wire going to

the Down terminal on the shade controller.

     • Connect the VIOLET/WHITE wire to the wire going to

the Up terminal on the shade controller.

5. Using two screws, securely mount the keypad to the

wallbox. See Figure C.

6. Install wallplate.

7.  Restore power feeding the shade controller(s).

Figure C - Keypad mounting

Twist wire

connector tight.

Be sure no bare

wire is exposed.

Figure B - WCK-4B-CC Keypad wiring

Twist wire

connector tight.

Be sure no bare

wire is exposed.

Caution - 

Do not over

tighten screws.

DOWN

UP

COMMON

VIOLET

GRAY

YELLOW

DOWN

UP

COMMON

VIOLET/WHITE

GRAY/WHITE

YELLOW/WHITE

G
N
D

D
W
N

U
P

      SHADE
CONTROLLER

G
N
D

D
W
N

U
P

     SHADE
CONTROLLER

22-24 AWG wire

DOWN

22-24 AWG wire

UP

COMMON

VIOLET

GRAY

YELLOW

G
N
D

D
W
N

U
P

      SHADE
CONTROLLER

Window Covering Keypad

Operating Instructions
Please Leave for Occupant