15
Panic Key Options
2-Button Panic Keys
All keypads offer a panic key function that allows users to send panic, emergency,
or fire reports to the central station in an emergency. Enable the panic key function
in the keypad user menu. Place the supplied icon stickers below the top row select
keys. The user must press and hold the two select keys for two seconds until a beep
is heard.
Panic
(left two select keys)—Zone 19 + Device Address
Emergency Non-Medical
(center two select keys)—Zone 29 + Device Address
Fire
(right two select keys)—Zone 39 + Device Address
7/0 Panic Keys
All keypads allow the user to initiate a panic alarm by pressing the 7 and 0 (zero)
keys at the same time for one-half (1/2) second. Enable the 7/0 Panic function in
Installer Options.
When enabled, all keypads send a Zone Short message to the panel
for the first zone of the keypad address. When the keys are released, a Zone Restore
message can be sent from the initiating keypad. To produce a panic alarm, program
the first zone of the keypad address as a panic type (PN) in panel programming.
Place a 1k Ohm end-of-line (EOL) resistor, DMP Model 311, across the white/brown
pair of zone wires on models 7070/A, 7073/A, 7170, and 7173. A Zone Restore
message sends when the keys are released. The 1k Ohm EOL resistor is not required on
7060/A, 7063/A, 7160, and 7163 keypads.
Keypad Interface