24
No Communication with Panel
(7063/A, 7073/A, 7163,7173)
This option defines the relay action when communication with
the panel has not occurred for five seconds. Press any top row
Select key to display CHOOSE ACTION. The default is RELAY
ALWAYS OFF.
Choose the action required:
1. Press the first select key to choose OFF (Relay Always Off)
—The relay does not turn on when any Wiegand string is
received. Off does not affect any REX operation.
2. Press the second select key to choose SITE
(Accept Site Code) — Door access is granted when the
Wiegand site code string received matches any site code
programmed at SITE CODE ENTRY.
3. Press the third select key to choose ANY (Any Wiegand
Read) — Door access is granted when any Wiegand string
is received.
4. Press the fourth select key to choose ON
(Relay Always On) — The relay is always on.
5. Press CMD and then the first select key to choose LAST
(Keep Last State)
—The relay remains in the same state and does not change
when communication is lost.
After choosing the action, NO COMM W PANEL and the
defined action display on the LCD. Programming is now
complete.
NO COMM WITH PANEL
RELAY ALWAYS OFF
CHOOSE ACTION
OFF SITE ANY ON
CHOOSE ACTION
LAST