09
6. Connections
Installation is simple once you understand how the DLM-4 Zone
Controller is connected to the fixtures. Please review the “Determining
HID Zones” section below and ensure that you have already
determined how your lighting zones will be laid out.
Extra interconnecting RJ12 communication cables can be purchased
in lengths of 25ft or 50ft. Select the correct length for your application.
(in below drawing the correct picture of the fixture)
DLM-4 Zone Controller cables are made specifically for use with
the DLM-4 Zone Controller. Other cables will not work properly and
improper operation may result.
The temperature sensors can be connected
ANYWHERE
within
the fixtures communication cabling. The temperature sensors send
information to the DLM-4 Zone Controller using the same cabling
to reduce installation and allow greater flexibility. To connect a
temperature sensor determine where the sensor will be located, and
then run a communication cable from the nearest ballast on that
zone, to the temperature sensor “T” connection.
*NOTE:
ONLY
use DLI cables and T-Splitters.
THIS BLANK LAYOUT GRID CAN BE USED TO DRAW THE
DESIRED PATTERN / LOCATION FOR THE FIXTURES.
Determining the Zones
Continued...
Once the lighting zones have been designed, the ballast can be
connected to the DLM-4 Zone Controller unit.
Each of the 4 available zones on the DLM-4 Zone Controller unit
will have a separate cable connection to connect to the fixtures
within each zone.
Simply connect a RJ12 cable to the desired zone connector on the
bottom of the DLM-4 Zone Controller, and then run the cable to
the nearest ballast to be controlled.
Each of the HID ballast is connected to the zone cabling using the
included cable “T” splitter and a short cable.
The splitter then connects the next ballast in line and repeats this
process until all of the fixtures are connected to the desired DLM-4
Zone Controller zone cable.
*NOTE:
The temperature sensor for each zone can be connected
ANYWHERE
along the zone cabling. The same type cable splitter is
used to connect the temperature sensor inline with the fixtures. The
signal from the temperature sensor communicates with the DLM-4
Zone Controller through the same cables that communicate with the
fixtures.
1
2
3
4
5
WARNING:
DO NOT
connect the power to the fixtures until all
of the settings are entered into the DLM-4 Zone Controller.
AVERTISSEMENT:
NE
branchez
PAS
l’alimentation sur les
accessoires tant que tous les paramètres n’ont pas été entrés
dans le régulateur de zone DLM-4.