9. Troubleshooting

9. Troubleshooting Continued...

Some of the most common issues or problems can be found within 
this section. Before returning the unit for service, please consult the 
troubleshooting points below, additional information can be found 
online at 

www.dutchlightinginnovations.com

The DLM-4 Zone Controller is 
connected to power, but it 
does not seem to be working 
/ no display

Check the low-volt power 
supply is plugged in properly 
to the DLM-4 Zone Controller.

After setting up the DLM-4 
Zone Controller, the fixtures 
are still not being turn on or 
controlled.

Each ballast must be manually 
switched to External (DLM-4 
Zone Controller) control. Verify 
the selector switches on the 
ballast are correct.

The 315 watt fixtures cannot be 
dimmed. However, they can be 
turned OFF if the temperature 
reaches the “Off At” setpoint. 

Within each Zone settings, 
you can select which 
temperature sensor you want 
to “assign” to that zone. Verify 
the Sensor setting is correct.

Make sure the temperature 
sensor is not receiving direct 
HID light which would increase 
the temperature reading.

The Zone does not seem 
to be controlled by the 
temperature sensor correctly.

The temperature display 
within one or more zones 
does not seem to be correct, 
reading high.

Power was interrupted to the 
unit, and now the lights will 
not turn on.

There is a 15-minute time delay 
after a power failure to prevent 
the lamps from hot-starts. 

The dimming function does 
not work for my 315 watt 
fixtures.

PROBLEM

RESOLUTION

WARNING: 

DO NOT 

allow theDLM-4 Zone Controller to be 

exposed to water or excessive heat. 

DO NOT 

open or attempt 

to repair or disassemble the controller, as there are no user-
serviceable parts inside. Opening the controller will void the 
warranty.

If the DLM-4 surface is dirty, wipe it with a dry towel. 
The DLM-4 operates under natural ventilation conditions.

AVERTISSEMENT: 

N’

exposez 

PAS

 le régulateur de zone DLM-4 

à de l’eau ou à une chaleur excessive.

 NE

 l’ouvrez 

PAS

NE

 tentez 

PAS

 de le réparer ou de le démonter, car il ne contient aucune 

pièce réparable par l’utilisateur. L’ouverture du régulateur 
entraîne l’annulation de la garantie.

Si la surface du DLM-4 est sale, essuyez-la à l’aide d’un chiffon 
sec. Le DLM-4 fonctionne sous des conditions de ventilation 
naturelle.

Содержание DLM-4 ZONE

Страница 1: ...DLM 4 ZONE Controller ...

Страница 2: ...novations fixtures The controller is equipped with an easy to use menu system in six languages English Spanish German Dutch French and Mandarin The DLM 4 Zone Controller can be connected to up to 4 separate zones of DLI lighting fixtures Each zone can control up to 255 lights and 1 sensor so in total you can control 1020 lights and 4 sensors Once connected to the HIDs the controller will monitor a...

Страница 3: ... cables and additional interconnect splitters can be purchased separately Ballast control is connected using RJ12 cables which are used to daisy chain the fixtures together Each of the ballasts comes with an RJ12 T splitter Each individual zone can have its own temperature sensor for more accurate control It is also possible to assign a specific temperature sensor to link with more than one lighti...

Страница 4: ...ted to the controller Each zone can have separate dimming actions to take place and each zone can have it own separate temperature sensor that monitors the zone temperature All of the zones are controlled individually based on the 24 hour timeclock built into the DLM 4 Zone Controller Having 4 zones allows the user to create multiple lighting layouts and dimming sequences based on their individual...

Страница 5: ...DESIRED PATTERN LOCATION FOR THE FIXTURES Determining the Zones Continued Once the lighting zones have been designed the ballast can be connected to the DLM 4 Zone Controller unit Each of the 4 available zones on the DLM 4 Zone Controller unit will have a separate cable connection to connect to the fixtures within each zone Simply connect a RJ12 cable to the desired zone connector on the bottom of...

Страница 6: ...een set to operate using the External control Turn the selector switch on the side of each of the ballast to the correct position to allow the DLM 4 Zone Controller to control the ballast NOTE If the ballast selector switch is NOT positioned to allow External DLM 4 Zone Controller control the ballast will function manually without control DO NOT CONNECT THE POWER CABLES ON THE BALLAST UNTIL THE DL...

Страница 7: ...em to be changed as well as to accept and enter the new setpoint into memory Familiarize yourself with the function of the 6 buttons on the front of the DLM 4 Zone Controller in order to able to access settings and to better understand how to use the DLM 4 Zone Controller to its greatest potential 7 1 Start Settings Once you have connected all of the Zone connections from the DLM 4 Zone Controller...

Страница 8: ...guration page press Enter to access the Configuration page Once the Configuration page is displayed use the Up and Down buttons to navigate to the desired setting Press Enter to highlight the desired setting Use the Up and Down buttons to adjust the line item to your desired setting Pressing Enter will accept the change After Configuration is complete pressing the Back button will return to the Ma...

Страница 9: ...an get to before shutting down the lighting zones This setting should normally be set at least 5 F up to 10 degrees F above the Dim at setting If the temperature continues to rise in the growing area the lights connected to each zone can be shut off to eliminate overheating of the growing area Sun R S time The DLM 4 Zone Controller can simulate Sunrise and Sunset By slowly raising and lowering the...

Страница 10: ...ed to 7 6 Temperature Min Max Page Pressing the Find button on the DLM 4 Zone Controller will access some important functions The first page that will be displayed is the Temperature Minimum Maximum page Each of the temperature sensors installed will constantly measure the temperature and record the maximum high and minimum low temperatures These recorded temperatures can be used to confirm that t...

Страница 11: ... current output status and at the time remaining before changing the ON OFF status 1 2 3 4 OVERRIDE FORCE PAGE Override Zone Force Zone 1 X 2 X 3 X 4 X 1 2 3 4 ON ON ON ON 04 09 07 04 09 07 04 09 07 04 09 07 Countdown 7 7 Manual OverRide Force page Occasionally the user may want to manually turn each lighting Zone On or Off manually Each of the 4 zones within the DLM 4 ZONE controller can be manua...

Страница 12: ...g to factory presetting select the System Setup page in the Main menu and then select Factory Reset Pressing Enter will bring you the Factory Reset confirmation page you will be asked to confirm the Factory Reset press Enter or to press the Back button to cancel the reset and return to the previous page FACTORY RESET PAGE System Setup Factory Reset Firmware Update Firmware V_2 7 SN 001EC0FAE110 Pr...

Страница 13: ...e needs to be updated follow the prompts on the computer to download a copy of the newest firmware onto a MicroSD card Insert the MicroSD card into the slot on the bottom of the DLM 4 Zone Controller unit Access the Firmware Update menu by going back to the System Setup menu and scrolling down to Firmware Update Press the Enter button to enter the firmware update menu Press Enter to scan the SD ca...

Страница 14: ...tails including time and date of the event temperature recorded and a description of the event will be created by the DLM 4 Zone Controller and stored within memory to be viewed later The controller can record and store a total of 10 events The messages are accessed by pressing the Find button to display the stored messages and then pressing the Enter button in order to clear reset the message log...

Страница 15: ...01 19 17 Zone 1 1000W Zone 2 Restrike Zone 3 Restrike Zone 4 Restrike 1000W70 7F 1000W Day F 14 31 F 14 31 F 14 31 7 14 Dimming and High temperature Shut Down The DLM 4 Zone Controller has the ability to monitor the temperature of 4 separate zones The user can select their desired dimming and high temp shut down Stop At settings within the zone settings Dim at setting If the temperature of any of ...

Страница 16: ...om the date of purchase of the original product All returns need to be done in the original packaging in order to avoid damages of the product during transport Defective products need to be returned to factory or service shop for repaiir Non professionals Do not open the cabinet to prevent electric shock or damage to the equipment Pour tout retour le produit doit être replacé dans son emballage d ...

Страница 17: ...receiving direct HID light which would increase the temperature reading The Zone does not seem to be controlled by the temperature sensor correctly The temperature display within one or more zones does not seem to be correct reading high Power was interrupted to the unit and now the lights will not turn on There is a 15 minute time delay after a power failure to prevent the lamps from hot starts T...

Страница 18: ...n électrique Degree of ingress protection Indice de protection Certifications Certifications 12vdc 200ma 12 V CC 200 mA Backlit 9 lines x 16 characters 1000 meters each zone 1 degree F ETL FCC ETL FCC IP20 IP20 FOUR separate zones each with separate temperature sensors 1 Standard Additional sensors can be added up to 4 total Not limited can be placed anywhere inside growing area Use between 0 45 C...

Страница 19: ...www dutchlightinginnovations com ...

Отзывы: