6. Insert flash memory
7. Select memory>zelio
8. Press menu/ok
9. Program will now transfer
10. Once done press menu/ok and scroll to run/stop
11. Select run
12. Select from non-volatile memory (first one on list) and press Ok
1. Prepare two buckets
a) One empty (orange one)
b) One with water up to 4.5 inches from the rim
2. Place probe over empty bucket first
3. Press and hold teach button until LED flashes
4. Release teach button and place the sensor over the orange bucket
5. Press and hold teach for 3 to 5 seconds and then release
6. Move sensor to bucket with water
7. Press and hold the teach for 3-5 seconds and then release (note you
need to move bucket to bucket within 20 seconds
8. Wait until the sensor flashes and changes color
9. Reinstall probe on sensor box
1. Press button 2
2. Using up/down keys set the alarm to 95
3. Wait 5 seconds for the reading to be set
1. Press button 3
2. Using up/down keys set the alarm to 5
3. Wait 5 seconds for the reading to be set
1. Press button 1 and using the up key [3] set the SP at 70 to start
2. Press button 4 to enter this value
3. After about 20 to 30 seconds the scrubber will start to fill
4. Monitor the water level using a tape measure
5. Readjust the SP to match the correct water level for the scrubber
10.7.2 Reprogramming Water Level Sensor - Tech Ultrasonic Probe
10.7.3 Reprogramming Water Level Sensor - Set High Water Level Alarm
10.7.4 Reprogramming Water Level Sensor - Set Low Water Level Alarm
10.7.5 Reprogramming Water Level Sensor - Set Water Level When Machine Off