16
8.6.3 Top Mount Blower Assembly
8.7.1 Water Inlet and Solenoid Valve
As previously noted
• Locate the middle section top bolting holes for securing the motor-blower assembly
• Lower the motor-blower carefully onto the middle section, watching for interference. Set the motor-blower assembly in place so that its base
structure bolt pattern matches the middle section bolt hole pattern
• Bolt the base structure of the motor-blower assembly to the middle section with bolt, lock washer, washer
• Insert connection flange between blower inlet flange and clean air section outlet
• Bolt to blower flange and clean air section with bolt, lock washer, washer, washer, nut
• Run motor electrical cable to the control box and see
section 8.8
for electrical connection
• Secure electrical cable to body with cable clamps
The water inlet solenoid will be provided with the Typhoon Central Dust Collector and
will need to be installed on site.
• Connect water inlet “L” piping
• Connect the water inlet solenoid
• Connect the blue pressure hose to the water inlet solenoid fitting and to the
clean air section pressure hose fitting
• Secure the blue pressure hose to the body with hose clamps
• Connect the solenoid leads to black, white, and green wires in accordance
with solenoid wiring diagram
• Run solenoid wire cable to the control box and see section 9.2.8 for
electrical connection
• Secure to electrical cable to body with cable clamps along lower section
and middle section bolting flange
• Connect the manual shut off valve
• Connect a 1/2” NPT water supply line to the manual shutoff valve with
standard pipe fittings.
8.7.2 Water Level Box
The water level box houses the water level sensor and will be provided with the Typhoon Central Dust Collector and may need to be installed on site.
• Connect level box to the main body. Connect outlet duct to body with hose
clamps and sealent