PR95 Operator’s Manual
Burst Pipe - 47
Connect
CMW
Connect
1.
Install towing head (2) onto end of new pipe
(1).
2.
Remove pilot rod assembly.
3.
Install bursting head (5) over rod (6) and slide
forward until threads are visible.
4.
Thread stop rod assembly (4) on end of rod
string.
5.
Connect stop rod assembly to towing head
with a shackle (3).