background image

EC-BOS-6

AX

MOUNTING AND WIRING INSTRUCTIONS

EC-BOS-6

AX

 Mounting and Wiring Instructions

Part Number: 05DI-HIBS6AX-10

Revised: February 2008

 

1

Information and specifications published here are current as of the date of publication of this document. Distech Controls, Inc. reserves the right to change or 
modify specifications without prior notice. The latest product specifications can be found by contacting our corporate headquarters. Products or features con-
tained herein may be covered by one or more U.S. or foreign patents. LON and L

ON

W

ORKS

 are registered trademarks of the Echelon Corp. Niagara

AX

 Frame-

work is a trademark of Tridium Inc. © 2008 Distech Controls, Inc.

This document covers the mounting and wiring of the EC-BOS-6

AX

 

series controller. It assumes that you are an engineer, technician, or 
service person who is performing control system installation. 
Instructions in this document apply to the following products:

Note

Not covered in this document is the Niagara

AX

 software installation and configuration required for a 

fully functioning unit. This includes setting host IP address and password, serial port configuration, and 
other parameters. Refer to the 

EC-BOS

AX

 Install and Startup Guide 

for this information. 

In addition, the mounting and wiring of EC-BOS-6

AX

 expansion options are covered in separate 

documents. See sections 

“About Expansion Options,”

 page 8, and 

“Related Documentation,”

 page 18.

These are the main topics included in this document:

  •

Preparation,

 page 2

  •

Precautions,

 page 4

  •

Mounting,

 page 5

  •

Board Layout,

 page 7

  •

About Expansion Options,

 page 8

  •

Wiring Details,

 page 11

  •

Power Up and Initial Checkout,

 page 16

Also included in this document are several appendixes, as follows:

  •

Using Status LEDs,

 page 19

  •

Maintaining the EC-BOS-6

AX

,

 page 20

  •

Replacement Parts,

 page 21

  •

Certifications,

 page 24

  •

Declaration of Conformity,

 page 25

Models

Models

Models

Models

Description

Description

Description

Description

EC-BOS-6

AX

EC-BOS-6

AX

 base unit controller, powered by 

(either):

EC-NPB-PWR 

DIN-mountable 24V power module

EC-NPB-PWR-UN DIN-mountable 90-263VAC power module

EC-WPM-

XX

Wall-mount universal AC power adapter, with 
different models available, where -

XX

 is either:

 

-US,  -EU, or -UK (vary by AC wall plug).

Содержание EC-BOS-6AX

Страница 1: ...nd configuration required for a fully functioning unit This includes setting host IP address and password serial port configuration and other parameters Refer to the EC BOSAX Install and Startup Guide for this information In addition the mounting and wiring of EC BOS 6AX expansion options are covered in separate documents See sections About Expansion Options page 8 and Related Documentation page 1...

Страница 2: ...4Vac in line DIN mount capable with grounding wire or EC NPB PWR UN 90 263Vac DIN mount capable with grounding wire EC WPM XX External wall mount power adapter input 90 254Vac 50 60 Hz output 15Vdc 1A where XX varies by the AC wall plug for installation locale EC WPM US U S or Japan installations EC WPM EU European installations type C plug EC WPM UK United Kingdom installations type B plug Materi...

Страница 3: ...for mounting DIN rail or if DIN rail not used for mounting bases of EC BOS 6AX controller and power module if used 2 phillips screwdriver used to install and remove optional communications modules Small flat blade screwdriver used for mounting or removing the EC BOS 6AX from DIN rail also for making wiring connections to RS 485 connector and optionally LON connectors ...

Страница 4: ...the EC BOS 6AX is 24Vac at 50 60 Hz or 24Vdc if using EC NPB PWR 90 to 263Vac at 50 60Hz if using EC NPB PWR UN or from 100 240Vac at 50 60 Hz if using EC WPM XX Disconnect power before installation or servicing to prevent electrical shock or equipment damage Make all connections in accordance with national and local electrical codes Use copper conductors only To reduce the risk of fire or electri...

Страница 5: ...lectrical contractors electrical machinery welding equipment and spark igniters Physical Mounting The following information applies about physically mounting the unit You can mount the EC BOS 6AX in any orientation It it not necessary to remove the cover before mounting Mounting on a 35mm wide DIN rail is recommended The EC BOS 6AX unit base has a molded DIN rail slot and locking clip as does the ...

Страница 6: ... from sliding on the DIN rail See Figure 1 below Figure 1 EC BOS 6AX and accessory mounting details Mounting on DIN Rail Removing from DIN Rail EC BOS 6AX EC BOS 6AX 345 mm 13 58 162 mm 6 38 104 mm 4 1 162 mm 6 38 EC NPB PWR Install DIN rail End Clip Stop Clip at both ends of final assembly DIN rail End Clip DIN Rail End Clip EC NPB PWR 263 mm 10 35 509 mm 20 04 427 mm 16 81 591 mm 23 27 52 mm 2 0...

Страница 7: ...ts is correct then push inwards to snap in place Board Layout Figure 2 shows the location of LEDs option slots and other features of the EC BOS 6AX with cover removed For a side view of communications ports and other features see Figure 5 on page 15 Figure 2 EC BOS 6AX board layout details BATTERY Option Slot 2 Option Slot 1 Battery Bracket on top of option cards if any Option Slot Connectors Stat...

Страница 8: ...AX see the previous Warning Step 2 Remove the cover See Removing and Replacing the Cover page 7 Step 3 Remove the battery and bracket assembly by taking out the four screws holding it in place setting the screws aside for later Unplug the battery from the connector on the EC BOS 6AX Step 4 Remove the blanking end plate for the slot you are installing the option card into Retain the blanking plate ...

Страница 9: ...ny connected modules and is located on the end of the EC BOS 6AX opposite to the option cards Warning Power to the EC BOS 6AX must be OFF when inserting or unplugging accessory modules Wait for all LED activity to stop all LEDs to be off Also do not connect live voltages to the inputs or outputs of an I O module EC NetAX IO 16 or EC NetAX IO 34 while it is in an un powered state before plugging th...

Страница 10: ...EC NetAX IO 34 DIN mountable combined 34 points I O with 24V isolated power module used to provide I O points as well as power EC BOS 6AX from a dedicated external Class 2 24Vac transformer or a 24Vdc power supply Only one EC NetAX IO 34 per EC BOS 6AX Provides the following I O points 16 Universal Inputs UIs 10 Digital Outputs DOs SPST relay type 8 Analog Outputs 0 10Vdc type Up to two additional...

Страница 11: ... 16 Grounding An earth ground spade lug 0 187 is provided on the base of the EC BOS 6AX for connection to earth ground For maximum protection from electrostatic discharge or other forms of EMI connect the supplied earth grounding wire to this lug and a nearby earth ground see Figure 3 on page 13 Keep this wire as short as possible Power is provided for EC BOS 6AX plug in accessory modules through ...

Страница 12: ...e of appropriate voltage To supply power to the EC BOS 6AX you then simply plug the barrel connector plug from the EC WPM XX into the barrel power connector on the EC BOS 6AX base board see Figure 5 on page 15 Caution Do not plug the barrel connector plug from the EC WPM XX into the EC BOS 6AX until all other mounting and wiring is completed See Power Up and Initial Checkout page 16 EC NPB PWR Usi...

Страница 13: ...alled EC NetAX IO 16 modules from AC line power with a universal input range from 90 263Vac If installing EC NetAX IO 16 modules the EC NPB PWR UN installs as the last end module in the chain See Figure 1 on page 6 Warning A 120Vac or 240Vac circuit powers the EC NPB PWR UN Disconnect power Disconnect power Disconnect power Disconnect power to this circuit before installation to prevent electrical...

Страница 14: ... grounding wire to a nearby grounding point See Figure 4 Step 5 Make AC circuit connections line mains and neutral to the terminals labeled INPUT PWR Step 6 Replace the cover on the EC NPB PWR UN Make sure all modules in the mounted assembly are firmly connected together and secured Caution Do not energize the AC circuit wired to the EC NPB PWR UN until all other EC BOS 6AX mounting and wiring is ...

Страница 15: ...imary port Serial There are two serial ports on the EC BOS 6AX base unit Each has a UART capable of operation up to 115 200 baud At the bottom of the board see Figure 5 the left port is an RS 232 port using an DB 9 plug male connector To the right of this is a two wire with shield isolated RS 485 port using a screw terminal connector plug Note A green receive LED and yellow transmit LED are provid...

Страница 16: ...s of the EC BOS 6AX battery connector status LEDs and barrel power connector for EC WPM XX only Refer to Figure 3 on page 13 for location of the power connector on the EC NPB PWR UN power module Following all mounting and wiring perform the following Procedure 4 Initial power up and checkout Step 1 Connect the Backup Battery Step 2 Apply Power Step 3 Check the Status LEDs Table 3 Serial port RS 23...

Страница 17: ...he power plug into either the EC BOS 6AX if wall mount AC adapter EC WPM XX or the 24V powered EC NPB PWR module If powering using the line voltage input EC NPB PWR UN power supply module energize the 90 263Vac circuit wired to the EC NPB PWR UN module Caution Do not connect both the EC WPM XX and EC NPB PWR EC NPB PWR UN supplies at the same time or equipment damage may result or a power outage m...

Страница 18: ...rimary power is lost or if the battery is uncharged or unable to hold a sufficient charge The battery should be replaced approximately every three years or more often if the unit is in a high temperature environment Note A NiMH battery characteristic is to lose charge if not left in charge mode trickle charge Leaving the battery unconnected or in the unit powered off will cause the battery to full...

Страница 19: ...e per second If the heartbeat LED stays on constantly does not light or blinks very fast more than once per second contact System Engineering for technical support Caution During boot up the heartbeat LED blinks in a 90 on 10 off pattern Do not remove power during this time or data loss may result I O module s firmware upgrade may be in progress Status The STATUS LED is located to the right of the...

Страница 20: ... ambient temperature has more to do with determining the life expectancy of the battery than does any other factor If the EC BOS 6AX is installed in a conditioned space the battery should provide dependable service for approximately three years average In an environment where the operating temperature is higher that is 50ºC or 122ºF you should only expect the battery to last approximately one year...

Страница 21: ...ffs Step 7 Place the four screws through the battery bracket option cards blanking plates and into the standoffs on the EC BOS 6AX base board Hand tighten these screws Step 8 Replace the cover Step 9 Restore power to the EC BOS 6AX and verify normal operation Replacement Parts Servicing the EC BOS 6AX may call for replacement parts There are three categories of parts Non replaceable Parts Standard...

Страница 22: ...ormal technical support resource to eliminate the possibility of a software issue or mis configuration problem Replacing the base assembly Caution Before handling circuit boards discharge any accumulated static by touching the metal surface of the EC BOS 6AX For details see the Static Discharge Precautions section on page 4 To replace the EC BOS 6AX base assembly in the field proceed as follows Pr...

Страница 23: ... or fastened by some sombinations See Figure 1 on page 6 for details on removal from and mounting onto the DIN rail c Remove any screws fastening the EC BOS 6AX and remove it see Figure 1 on page 6 Step 6 Remove the cover from the old EC BOS 6AX see Removing and Replacing the Cover page 7 Note the position of installed option boards if any You must transfer them to the replacement EC BOS 6AX Step ...

Страница 24: ...igned to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area may cause interference in which case users at their own expense will be required to take whatever measures may be required to correct the interference Any unauthorized modification of this equipment may result in the revocation of the owner s ...

Страница 25: ...Applied EMC Standards Applied Standard EN 61000 6 4 Description Electro Magnetic Compatibility Emissions Generic Criteria Met Complies EN 61000 6 2 and EN 61000 6 1 as defined below Electro Magnetic Compatibility Immunity Complies as documented below EN50081 2 Generic Emission Standard for residential commercial and light industrial environment CISPR 11 Limits of Radio Disturbance Radiated Emissio...

Страница 26: ...m 2 50 EC NetAX IO 16 or EC NPM PWR or EC NPB PWR UN 88 55mm 3 48 82 55mm 3 25 Tip If mounting accessory modules future removal replacement of the EC BOSAX is simplified if you do not install screws in the accessory module side tabs of the EC BOSAX see above EC BOS 6AX EC NetAX IO 16 or EC NPM PWR or EC NPB PWR UN Distance between center of tabs from one unit to another unit Accessory module side ...

Страница 27: ......

Страница 28: ...Distech Controls Inc 4005 B Boul Matte Brossard QC J4Y 2P4 Tel 1 800 404 0043 North America Tel 1 450 444 9898 International 05DI HIBS6AX 10 05DI HIBS6AX 10 ...

Отзывы: