background image

© 2004 Directed Electronics, Inc. Vista, CA

2

23

3

5. 

R

Reelleeaassee..  Release the Valet®/Program switch.

TTo

o  aacccceessss  aan

no

otth

heerr  ffeeaattu

urree::

You can advance from feature to feature by pressing and releasing the Valet

®

/Program switch the number of times

necessary to get from the feature you just programmed to the feature you wish to access. For example, if you

just programmed Feature 1 and you want to program Feature 2:

1. Release the Valet

®

/Program switch.

2. Press and release the Valet/Program switch once to advance from Feature 1 to Feature 2.

3. Press the Valet

®

/Program switch once more and H

HO

OLLD

D it.

4. The siren will chirp two times to confirm that you have accessed Feature 2.

TTo

o  eexxiitt  tth

hee  CCo

od

dee  LLeeaarrn

niin

ng

g,,  d

do

o  o

on

nee  o

off  tth

hee  ffo

ollllo

ow

wiin

ng

g::

Close the open door. 

Turn the ignition on.

No activity for longer than 15 seconds.

Press the Valet®/Program switch too many times.

ffeeaattuurreess  m

meennuu

FFEEA

ATTU

UR

REE

D

DEEFFA

AU

ULLTT  LLEED

D  O

ON

N  SSEETTTTIIN

NG

GSS

LLEED

D  O

OFFFF  SSEETTTTIIN

NG

GSS

N

NU

UM

MB

BEER

R

((P

PR

REESSSS  TTR

RA

AN

NSSM

MIITTTTEER

R  B

BU

UTTTTO

ON

N  II))

((P

PR

REESSSS  TTR

RA

AN

NSSM

MIITTTTEER

R  B

BU

UTTTTO

ON

N  IIII))

1

A

Accttiivvee  A

Arrm

miin

ng

g

Passive Arming

2

CCo

on

nffiirrm

maattiio

on

n  CCh

hiirrp

pss  O

ON

N

Confirmation Chirps OFF

3

IIg

gn

niittiio

on

n--CCo

on

nttrro

olllleed

d  

Ignition-controlled 

D

Do

oo

orr  LLo

occkk//U

Un

nllo

occkk  O

ON

N

Door Lock/Unlock OFF

4

A

Accttiivvee  LLo

occkkiin

ng

g

Passive Locking

5

0

0..8

8--sseecco

on

nd

d  D

Do

oo

orr  LLo

occkk  P

Pu

ullssee  D

Du

urraattiio

on

n

3.5-second Door Lock Pulse Duration

6

D

Do

ou

ub

bllee  P

Pu

ullssee  U

Un

nllo

occkk  O

OFFFF

Double Pulse Unlock ON

7

SStteeaalltth

h  CCo

od

diin

ng

g™

™  TTeecch

hn

no

ollo

og

gyy  O

ON

N

Stealth Coding™ Technology OFF

8

D

Do

oo

orr  ttrriig

gg

geerr  eerrrro

orr  cch

hiirrp

p  O

ON

N

Door trigger error chirp OFF

9

LLo

occkk  p

pu

ullssee  SSiin

ng

gllee

Lock pulse Double

10

CCo

om

mffo

orrtt  ccllo

ossu

urree  O

OFFFF

Comfort closure ON (20-seconds)

N

NO

OTTEE:: Factory defaults are indicated in b

bo

olld

d type.

Содержание Hornet 740T

Страница 1: ...M Mo od de ell 7 74 40 0T T I In ns st ta alllla at tiio on n G Gu uiid de e 2004 Directed Electronics Inc Vista CA N740T 09 04...

Страница 2: ...umper 18 o on n b bo oa ar rd d d du ua al l s st ta ag ge e z zo on ne e 2 2 i im mp pa ac ct t s se en ns so or r 1 18 8 b by yp pa as ss si in ng g s se en ns so or r i in np pu ut ts s 1 19 9 t tr...

Страница 3: ...T TY Y O OU UT TP PU UT T R RE ED D 1 12 2V V C CO ON NS ST TA AN NT T P PO OW WE ER R I IN NP PU UT T B BR RO OW WN N S SI IR RE EN N O OU UT TP PU UT T Y YE EL LL LO OW W I IG GN NI IT TI IO ON N I...

Страница 4: ...Internal Programming Jumper section of this guide P P N N 8 86 61 17 7 or a standard automotive SPDT relay must be used on the H1 2 light flash output harness wire This wire provides a 200 mA output...

Страница 5: ...tant trigger Inputs shorter than 0 8 seconds will trigger the Warn Away response while triggers longer than 0 8 seconds will instantly trigger the full alarm cycle This wire is ideal for hood and trun...

Страница 6: ...nd when the door is closed This wire will report Zone 3 Remove any paint and connect this wire to bare metal preferably with a factory bolt rather than your own screw Screws tend to either strip or lo...

Страница 7: ...system receives the code controlling Channel 2 for longer than 1 5 seconds the red white wire will supply an output as long as the transmission continues This is often used to operate a trunk hatch r...

Страница 8: ...m I IM MP PO OR RT TA AN NT T If you mistake a Type C direct wired system for a Type A positive pulse system the module will be damaged H He er re e i is s a a t te es st t C Cu ut t t th he e w wi ir...

Страница 9: ...pickups 1989 later many of the S10 Blazers the Corvette 95 Cavalier Sunfire 1993 and newer Camaro Firebird all use Type C door locks and cannot be controlled without a 451M Almost all domes tically bu...

Страница 10: ...ground all the time One wire will pulse when the switch locks the doors and the other wire will pulse when the switch unlocks the doors This type of system is difficult to mistake for any other type...

Страница 11: ...ated one of the target wires The switch that lost all operation is the master switch If one switch works both directions and the other switch works only one direction you have a Type A system If both...

Страница 12: ...ing the door lock actuator inside the door Other vehicles may only require one actuator installed in the driver s door if all door locks are operated when the driver s lock is used This type of instal...

Страница 13: ...system can be controlled with just two relays optional The control wire can be found in either kick panel and will show 12V when doors are unlocked and ground when doors are locked To interface see di...

Страница 14: ...me Mazda MPV s and some Mitsubishi s One relay optional is used to interface to this type of system as follows This system is most commonly found in Ford Mazda Chrysler and GM vehicles The door lock s...

Страница 15: ...der in half 2 Test with the meter from the switch side of the cut door lock switch key cylinder wire to a reliable constant 12V source Some good constant 12V references are the power input source to t...

Страница 16: ...or all testing use a calibrated digital multimeter that is set to ohms 1 Cut the output wire from the door lock switch key cylinder in half 2 Test with the meter from the switch side of the cut door l...

Страница 17: ...lug into the control module The LED system status indicator plugs into the white two pin port while the Valet Program switch should be plugged into the blue two pin port The status LED and Valet Progr...

Страница 18: ...r parking light circuits that draw 10 amps or more the internal jumper must be switched to a light flash output P P N N 8 86 61 17 7 or a standard automotive SPDT relay must be used on the H1 2 light...

Страница 19: ...6 BLUE wire without triggering the unit When the 5 second bypass period ends if the unit detects ground on the H1 6 BLUE wire all trigger inputs except the door trigger input will remain bypassed unt...

Страница 20: ...er Configuration section of this guide to program the Auto learn Standard Configuration on a three button transmitter C CH HA AN NN NE EL L P PR RE ES SS S A AN ND D R RE EL LE EA AS SE E N NU UM MB B...

Страница 21: ...i if f Ignition is turned off Door is closed Valet Program button is pressed too many times More than 15 seconds elapses between steps One long chirp indicates that Code Learning has been exited t tr...

Страница 22: ...Program switch the number of times corresponding to the feature number you want to program see the Features Menu section of this guide The LED ON settings listed in the Features Menu table are the fa...

Страница 23: ...D D O ON N S SE ET TT TI IN NG GS S L LE ED D O OF FF F S SE ET TT TI IN NG GS S N NU UM MB BE ER R P PR RE ES SS S T TR RA AN NS SM MI IT TT TE ER R B BU UT TT TO ON N I I P PR RE ES SS S T TR RA AN...

Страница 24: ...will accommodate door lock interface in these vehicles The default setting is 0 8 second door lock pulses See Mercedes Benz and Audi 1985 and Newer Type E Door Locks section diagram 6 6 D DO OU UB BL...

Страница 25: ...tem will not monitor the zone inputs for Bypass Notification Warn away or Full trigger inputs until after the 20 second timer has completed to avoid any false triggering of the system while the window...

Страница 26: ...of door switch system This often happens when the wrong door input has been used See H1 5 GREEN Door Trigger Input Primary Harness Wire Connection Guide section of this guide S Sy ys st te em m w wi i...

Страница 27: ...sw wi it tc ch h d do oe es s n no ot t w wo or rk k Is it plugged into the correct socket See Plug In LED and Valet Program Switch section of this guide T Th he e L LE ED D s sy ys st te em m s st ta...

Страница 28: ...2 28 8 2004 Directed Electronics Inc Vista CA...

Страница 29: ...runk Hood Input Zone 1 Violet Door Trigger Input Zone 3 Black Chassis Ground Brown Siren output 1A Red Constant Power Red White 200 mA Channel 2 Auxiliary Output 200 mA Chassis Ground Optional Accesso...

Отзывы: