iinntteerrnnaall pprrooggrraam
mm
miinngg jjuum
mppeerr
This jumper is used to determine the light flash output. In the (+) position, the on-board relay is enabled and
the unit will output (+)12V on the H1/2 WHITE wire. In the (-) position, the on-board relay is disabled. The H1/2
WHITE wire will supply a (-) 200 mA output suitable for driving factory parking light relays. To access the jumper,
open the control module.
N
NO
OTTEE:: For parking light circuits that draw 10 amps or more, the internal jumper must be switched
to a (-) light flash output. P
P//N
N 8
86
61
17
7 or a standard automotive SPDT relay must be used on the
H1/2 light flash output harness wire.
oonn--bbooaarrdd dduuaall ssttaaggee zzoonnee 22 iim
mppaacctt sseennssoorr
There is a dual-stage impact sensor inside the control unit. Adjustments are made via the rotary control as indi-
cated above. Since the impact sensor does not work well when mounted firmly to metal, we recommend against
lliigghhtt ffllaasshh jjuum
mppeerr
TO CHANGE
JUMPER
SETTINGS
DRW-298
(-) Light flash output
(+) Light flash output (default)