background image

© 2004 Directed Electronics, Inc. Vista, CA

3

3

wwhhaatt  iiss  iinncclluuddeedd

The control module

A high-powered siren

Two 3-button remote transmitters

The 12-pin primary harness 

The plug-in LED system status indicator

The 3-pin door lock harness

The plug-in Valet/Program switch

The plug-in starter interrupt harness

An on-board zone 2 impact sensor

pprriim

maarryy  hhaarrnneessss  ((HH11))  wwiirree  ccoonnnneeccttiioonn  gguuiiddee

______

______

______

______

______

______

______

______

______

______

______

______

This wire supplies (-) ground as long as the system is armed. This output ceases as soon as the system is disarmed.

It can be used to turn on an optional sensor or to control an optional accessory, such as a window module or

pager.

H

H1

1//1

1  O

OR

RA

AN

NG

GEE  ((--))  g

grro

ou

un

nd

d--w

wh

heen

n--aarrm

meed

d  5

50

00

0  m

mA

A  o

ou

uttp

pu

utt

R

REED

D//W

WH

HIITTEE

((--))  2

20

00

0  m

mA

A  CCH

HA

AN

NN

NEELL  2

2  V

VA

ALLIID

DIITTY

Y  O

OU

UTTP

PU

UTT

R

REED

D

((+

+))1

12

2V

V  CCO

ON

NSSTTA

AN

NTT  P

PO

OW

WEER

R  IIN

NP

PU

UTT

B

BR

RO

OW

WN

N

((+

+))  SSIIR

REEN

N  O

OU

UTTP

PU

UTT

Y

YEELLLLO

OW

W

((+

+))  IIG

GN

NIITTIIO

ON

N  IIN

NP

PU

UTT,,  ZZO

ON

NEE  5

5

B

BLLA

ACCK

K  

((--))  CCH

HA

ASSSSIISS  G

GR

RO

OU

UN

ND

D  IIN

NP

PU

UTT  

V

VIIO

OLLEETT

((+

+))  D

DO

OO

OR

R  TTR

RIIG

GG

GEER

R  IIN

NP

PU

UTT,,  ZZO

ON

NEE  3

3

B

BLLU

UEE

((--))  M

MU

ULLTTIIP

PLLEEX

X  TTR

RIIG

GG

GEER

R  IIN

NP

PU

UTT,,  ZZO

ON

NEE  1

1

G

GR

REEEEN

N

((--))  D

DO

OO

OR

R  TTR

RIIG

GG

GEER

R  IIN

NP

PU

UTT,,  ZZO

ON

NEE  3

3

B

BLLA

ACCK

K//W

WH

HIITTEE

((--))  2

20

00

0 m

mA

A  IIN

NTTEER

RIIO

OR

R  LLIIG

GH

HTT  IILLLLU

UM

MIIN

NA

ATTIIO

ON

N  O

OU

UTTP

PU

UTT

W

WH

HIITTEE//B

BLLU

UEE

((--))  2

20

00

0  m

mA

A  CCH

HA

AN

NN

NEELL  3

3  V

VA

ALLIID

DIITTY

Y  O

OU

UTTP

PU

UTT

W

WH

HIITTEE

((+

+//--))  SSEELLEECCTTA

AB

BLLEE  LLIIG

GH

HTT  FFLLA

ASSH

H  O

OU

UTTP

PU

UTT

O

OR

RA

AN

NG

GEE

((--))  5

50

00

0  m

mA

A  G

GR

RO

OU

UN

ND

D--W

WH

HEEN

N--A

AR

RM

MEED

D  O

OU

UTTP

PU

UTT  

H

H1

1//1

1

H

H1

1//2

2

H

H1

1//3

3

H

H1

1//4

4

H

H1

1//5

5

H

H1

1//6

6

H

H1

1//7

7

H

H1

1//8

8

H

H1

1//9

9

H

H1

1//1

10

0

H

H1

1//1

11

1

H

H1

1//1

12

2

Содержание Hornet 740T

Страница 1: ...M Mo od de ell 7 74 40 0T T I In ns st ta alllla at tiio on n G Gu uiid de e 2004 Directed Electronics Inc Vista CA N740T 09 04...

Страница 2: ...umper 18 o on n b bo oa ar rd d d du ua al l s st ta ag ge e z zo on ne e 2 2 i im mp pa ac ct t s se en ns so or r 1 18 8 b by yp pa as ss si in ng g s se en ns so or r i in np pu ut ts s 1 19 9 t tr...

Страница 3: ...T TY Y O OU UT TP PU UT T R RE ED D 1 12 2V V C CO ON NS ST TA AN NT T P PO OW WE ER R I IN NP PU UT T B BR RO OW WN N S SI IR RE EN N O OU UT TP PU UT T Y YE EL LL LO OW W I IG GN NI IT TI IO ON N I...

Страница 4: ...Internal Programming Jumper section of this guide P P N N 8 86 61 17 7 or a standard automotive SPDT relay must be used on the H1 2 light flash output harness wire This wire provides a 200 mA output...

Страница 5: ...tant trigger Inputs shorter than 0 8 seconds will trigger the Warn Away response while triggers longer than 0 8 seconds will instantly trigger the full alarm cycle This wire is ideal for hood and trun...

Страница 6: ...nd when the door is closed This wire will report Zone 3 Remove any paint and connect this wire to bare metal preferably with a factory bolt rather than your own screw Screws tend to either strip or lo...

Страница 7: ...system receives the code controlling Channel 2 for longer than 1 5 seconds the red white wire will supply an output as long as the transmission continues This is often used to operate a trunk hatch r...

Страница 8: ...m I IM MP PO OR RT TA AN NT T If you mistake a Type C direct wired system for a Type A positive pulse system the module will be damaged H He er re e i is s a a t te es st t C Cu ut t t th he e w wi ir...

Страница 9: ...pickups 1989 later many of the S10 Blazers the Corvette 95 Cavalier Sunfire 1993 and newer Camaro Firebird all use Type C door locks and cannot be controlled without a 451M Almost all domes tically bu...

Страница 10: ...ground all the time One wire will pulse when the switch locks the doors and the other wire will pulse when the switch unlocks the doors This type of system is difficult to mistake for any other type...

Страница 11: ...ated one of the target wires The switch that lost all operation is the master switch If one switch works both directions and the other switch works only one direction you have a Type A system If both...

Страница 12: ...ing the door lock actuator inside the door Other vehicles may only require one actuator installed in the driver s door if all door locks are operated when the driver s lock is used This type of instal...

Страница 13: ...system can be controlled with just two relays optional The control wire can be found in either kick panel and will show 12V when doors are unlocked and ground when doors are locked To interface see di...

Страница 14: ...me Mazda MPV s and some Mitsubishi s One relay optional is used to interface to this type of system as follows This system is most commonly found in Ford Mazda Chrysler and GM vehicles The door lock s...

Страница 15: ...der in half 2 Test with the meter from the switch side of the cut door lock switch key cylinder wire to a reliable constant 12V source Some good constant 12V references are the power input source to t...

Страница 16: ...or all testing use a calibrated digital multimeter that is set to ohms 1 Cut the output wire from the door lock switch key cylinder in half 2 Test with the meter from the switch side of the cut door l...

Страница 17: ...lug into the control module The LED system status indicator plugs into the white two pin port while the Valet Program switch should be plugged into the blue two pin port The status LED and Valet Progr...

Страница 18: ...r parking light circuits that draw 10 amps or more the internal jumper must be switched to a light flash output P P N N 8 86 61 17 7 or a standard automotive SPDT relay must be used on the H1 2 light...

Страница 19: ...6 BLUE wire without triggering the unit When the 5 second bypass period ends if the unit detects ground on the H1 6 BLUE wire all trigger inputs except the door trigger input will remain bypassed unt...

Страница 20: ...er Configuration section of this guide to program the Auto learn Standard Configuration on a three button transmitter C CH HA AN NN NE EL L P PR RE ES SS S A AN ND D R RE EL LE EA AS SE E N NU UM MB B...

Страница 21: ...i if f Ignition is turned off Door is closed Valet Program button is pressed too many times More than 15 seconds elapses between steps One long chirp indicates that Code Learning has been exited t tr...

Страница 22: ...Program switch the number of times corresponding to the feature number you want to program see the Features Menu section of this guide The LED ON settings listed in the Features Menu table are the fa...

Страница 23: ...D D O ON N S SE ET TT TI IN NG GS S L LE ED D O OF FF F S SE ET TT TI IN NG GS S N NU UM MB BE ER R P PR RE ES SS S T TR RA AN NS SM MI IT TT TE ER R B BU UT TT TO ON N I I P PR RE ES SS S T TR RA AN...

Страница 24: ...will accommodate door lock interface in these vehicles The default setting is 0 8 second door lock pulses See Mercedes Benz and Audi 1985 and Newer Type E Door Locks section diagram 6 6 D DO OU UB BL...

Страница 25: ...tem will not monitor the zone inputs for Bypass Notification Warn away or Full trigger inputs until after the 20 second timer has completed to avoid any false triggering of the system while the window...

Страница 26: ...of door switch system This often happens when the wrong door input has been used See H1 5 GREEN Door Trigger Input Primary Harness Wire Connection Guide section of this guide S Sy ys st te em m w wi i...

Страница 27: ...sw wi it tc ch h d do oe es s n no ot t w wo or rk k Is it plugged into the correct socket See Plug In LED and Valet Program Switch section of this guide T Th he e L LE ED D s sy ys st te em m s st ta...

Страница 28: ...2 28 8 2004 Directed Electronics Inc Vista CA...

Страница 29: ...runk Hood Input Zone 1 Violet Door Trigger Input Zone 3 Black Chassis Ground Brown Siren output 1A Red Constant Power Red White 200 mA Channel 2 Auxiliary Output 200 mA Chassis Ground Optional Accesso...

Отзывы: