32
z
Press
of the remote control to decrease sensitivity.
z
The sensor Primary zone can be tested at any time dur-
ing adjustment and will generate 1 siren chirp each
time the zone is activated.
4.
Press
to adjust Warn-Away zone
z
Siren chirps 1 time.
z
Warn-away Zone adjustment has now been entered.
z
Warn-away Zone can now be adjusted.
5.
Adjust Warn-away Zone
z
Press to
increase
sensitivity.
z
Press to
decrease
sensitivity.
z
The sensor Warn-away zone can be tested at any time
during adjustment and will generate 1 siren chirp each
time the zone is activated.
6.
Press
of the remote control to return to Primary zone
adjustment and lock in Warn Away zone setting.
z
Siren chirps 2 times
z
Primary zone can now be re-adjusted as described in
step 3.
z
Or press
again to lock in primary zone setting
and exit programming mode.
z
The siren will chirp 3 times when sensor adjustment
mode has been exited.
z
Auto-Scroll for adjusting sensitivity
- press and
hold
or
to increase or decrease sensitivi-
ty setting several levels rapidly.