arm/disarm diagnostic chart
table of zones
The zone number is the number of LED flashes used by the system to
identify a specific input. The standard input assignments are listed
below, along with spaces to write in any optional sensors or switches
you have had installed. If the Warning Zone response is triggered, the
LED will not report it.
Zone - Number
Dealer-Installed
of LED Flashes
Description
Options
1
Proximity sensor
2
Not used
3
Mux 1 trigger - for optional
sensors
4
Door switch trigger
5
Instant trigger - trunk
6
Instant trigger - hood
7
Ignition trigger
8
Mux 2 trigger - for optional
sensors
9
Not used
10
Power interrupt
Action
Chirps
Light Flashes
Description
Arm
2
2
System armed
Arm
4
4
System armed with hood/
trunk active and bypassed
(zones 5 and 6)
Arm
2 (5 sec.) 4
2 (5 sec.) 4
System armed with door
active and bypassed (zone 4)
Arm
2 (10 sec.) 4
2 (10 sec.) 4
System armed with sensor
active and bypassed zones
1, 3, and 8
Disarm
1
1
System disarmed
Disarm
3
3
System disarmed with
tamper alert