![Dini Argeo 3590EKR Series Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/dini-argeo/3590ekr-series/3590ekr-series_user-manual_2505697039.webp)
3590EKR, 3590EXP, 3590EXT series indicator
E-AF08_02_13.07_EN_U
39
15.5 SET-POINT FUNCTION
The indicator is supplied with 4 outputs (optional) that can be used for different functions, besides, through the I/O
expansion board (optional) it is possible to use another 12.
In the
SEtuP
>>
outPut
>>
r.ConF.
menu
(TECH.MAN.REF.)
it is possible to set the characteristics of each output which
will be used: normally open or normally closed; upon direct control or weight stability, with hysteresis or without, the
functioning mode.
It is also possible to set whether the enabling of the output excludes the check on the previous outputs (see the
SEtuP
>>
outPut >>
r.ModE
parameter).
15.5.1 NORMAL FUNCTIONING MODE
By setting the
SEtuP
>>
outPut >> r.ModE
parameter on “norMAL”, one configures the independent use of the outputs:
-
the check is always made on all the set outputs
-
the enabling of one of these does not provoke the disabling of the others.
15.5.1.1 SETPOINT ON THE GROSS WEIGHT
Functioning with hysteresis
(
rL.iSt
“HYSTERESIS” parameter set as
iSt.on
)
By selecting this functioning mode the output function on the GROSS weight is activated; one enters two SET POINTS for
each output: a DISABLING one, which, when the gross weight is lower than it, disables the appropriate output; an
ENABLING one, which, when the gross weight is greater or equal than it, it enables the appropriate output. Through
function
202
, combinable with the desired key (
<< F.KEYS >>
step,
TECH.MAN.REF.
), the SET POINT values are entered
(DISABLING and ENABLING) for each configured output:
-
The Led display shows " S.1 on " (relay 1 ENABLING SETPOINT): press
ENTER
,
enter the weight value with the
keyboard and confirm with
ENTER
(use the
C
key to quickly zero the current value).
-
The LED display shows " S.1 oFF” (relay 1 DISABLING SETPOINT): press
ENTER
,
enter the weight value with the
keyboard and confirm with
ENTER
(use the
C
key to quickly zero the current value).
-
Proceed in the same way for the following outputs (if present).
-
When finished programming the set points, exit with the
C
key.
Functioning without hysteresis
(
rL.iSt
“HYSTERESIS” parameter set as
iSt.oFF
)
The operating mode is the same as the previous one, except that just one SETPOINT is entered for each output (“S.1 on”);
for this purpose
the access to the " S.1 oFF " parameter is inhibited
.
NOTES
-
If all the outputs have the “NONE” (none) functioning mode,
the enabling of the 202 function has no effect.
-
The DISABLING SETPOINT must be less or equal to the ENABLING ones; if a value greater than the ENABLING one
is entered and confirmed in the DISABLING SETPOINT, the indicator will set at 0 the set point, until a correct value is
entered.
If a value lower than the DISABLING one is entered and confirmed in the ENABLING SETPOINT, that value is
accepted, but the DISABLING SETPOINT is put at 0.
-
The 0 value is valid on both the set point values.
-
The SETPOINT check of the weight remains active on the present value even during the modification of the SET
POINT, until the new value is confirmed.
-
At start-up, the relays are managed from when the weight is displayed and these take on the configuration set in the
set-up environment. These are not managed inside the technical set-up.
-
In case of weight not valid (local or from remote scale) all the outputs will be disabled.
ENABLED
DISABLED
S1on
S1oFF
OUT1 STATUS
GROSS WEIGHT