7.1.1 SEMIAUTOMATIC TARE
By pressing the
TARE
key one tares any weight which is on the scales; the LED display shows
“tArE”
for an instant and
then 0 (net weight); the
NET
and
T
LED turn on; the stored tare value is shown on the LCD display, see section
“DISPLAYED DATA”.
NOTES:
1) The LCD display shows the gross weight value and the stored tare value, identified with “PT” (Preset Tare)
.
In the printout, the tare is identified with “PT” (Preset Tare).
2) The tare function in the wheel weight mode, will be carried out only if:
-
the weight shown on the LED display is the sum weight of the active scales.
-
the weight present on the scales, is of AT LEAST FIVE DIVISIONS AND IS STABLE (
~
instability led is off) and VALID
(In other words the OVERLOAD condition must not be created).
7.1.2 PRESET TARE
To enter
the tare value, with the keyboard, type the desired tare value, one digit at a time; and press
TARE
.
The
C
key quickly clears the digited value.
The indicator automatically subtracts the entered value from the displayed weight, (the
NET
and
T
or
,
indicators turn
on),
as long as it is not greater than the instrument’s maximum capacity.
The display shows furthermore the stored tare value, identified with “PT” (Preset Tare)
.
In any case, when a new Tare value is entered, the preceding one is cancelled and substituted.
NOTE:
In the printout, the manual tare is identified with “PT” (Preset Tare).
7.2 TARE FUNCTION IN “AXLE WEIGHING” MODE
Unlike in the “wheel weighing” mode, the tare value in the axle weighing mode can be inserted only manually and it is not
subtracted from the displayed weight value, but from the sum total of the totalized axles, in other words, the partial total. By
inserting a tare value the
NET
and
T
pilot lights will not be managed since the LED display, will continue showing the
sum weight of the active scales.
It will be possible to view the stored tare value on the LCD display, see section “DISPLAYED DATA”.
To enter
the tare value with the keyboard type the value (including the decimal point) and press
TARE
. The
C
key quickly
zeros the current value.
The LCD display shows the gross weight value and the stored tare value, identified with “PT” (Preset Tare)
.
NOTES
1) In the “axle weighing” functioning mode, in any case, the LED display shows the gross weight also in the presence of a
tare.
2) The LCD display shows the gross weight value and the stored tare value, identified with “PT” (Preset Tare)
.
In the printout, the tare is always identified with “PT” (Preset Tare).
3) A new operation automatically cancels and substitutes the previous one, only if the weighing of vehicle is done.
4) The tare function in the axle weighing mode, will be carried out only if:
-
the weight shown on the LED display is the sum weight of the active scales.
-
the weight present on the scales, is of AT LEAST FIVE DIVISIONS AND IS STABLE (
~
instability led is off) and VALID
(In other words the OVERLOAD condition must not be created).
7.3 MANUAL CALCULATED TARE
With the “CALCULATOR” function it is possible to add or to subtract to the current tare the result of the operation between
two values enterable with the keyboard.
For the functioning specifications see the
“CALCULATOR” section.
7.4 TARE CANCELLATION
To cancel
the tare, press the
TARE
key with
unloaded
platform (only in the wheel weighing mode)
-
Press in sequence the numeric 0 key and
TARE
.
-
Press the
C
key in both cases.
NOTES:
The tare will be cleared only if the weight shown on LED display, is the sum weight of the active scales.
The tare in the axle weighing mode will be cleared only if the weighing of the vehicle is finished (reset of the partial total).