![Dini Argeo 3590EKR Series Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/dini-argeo/3590ekr-series/3590ekr-series_user-manual_2505697011.webp)
3590EKR, 3590EXP, 3590EXT series indicator
E-AF08_02_13.07_EN_U
11
2nd F
-
If pressed together with the other keys, it allows carrying out a specific function. (see section “"2ndF"
KEY: SECOND FUNCTION OF THE KEYS”).
-
In the
<< F.Keys >>
step, if pressed for an instant, the list of the available functions appear and it is
possible to choose one of them.
./HELP
-
If pressed in some steps or functions of the weight indicator, the display shows the keys and their
functions specific to that state of the instrument.
-
In the numeric or alphanumeric input phase, it enters, in this order, the following characters:
. , ; : # <
> \ | ” % & / ( ) = ? ^ ’ [ ] { }
;
- HELP function, see section “HELP MENU”.
F1
- By entering a number through numerical keyboard and then pressing the F1 key, one can quickly
select the database item corresponding to the entered value (the article must have already been
edited).
- In the numeric or alphanumeric input phase, it allows to copy entered characters.
- If pressed for an instant it allows entering the database.
- If pressed at length one locks and unlocks the instrument’s keyboard (except the
C
key)
F2
- In the numeric or alphanumeric input phase, it allows to stick with copied characters.
- If pressed for an instant it allows to insert the coordinates of the active scale.
- If pressed at length the weight visualization function with sensitivity x 10 is enabled.
F3
- If pressed for an instant it allows to insert the number of weighs after which it will be printed and the
partial total is cleared. If the value to be inserted is equal to 0, the automatic printing is disabled.
- If pressed at length one can adjust the date and time of the instrument.
F4
- If pressed for an instant it allows filling in the free texts, if configured.
- If pressed at length one enters the instrument’s diagnostics menu.
F5
- Commands the data transmission to the printer serial port.
- If pressed at length one locks/unlocks the tare.
F6
- If pressed for an instant it allows to totalize the weight on the weighing system.
- Allow to scroll forwards in the menu steps or in the parameters inside a step.
- In the numeric or alphanumeric input phase, it decrements the blinking digit.
F7
- If pressed for an instant, it allows to enter the combination of scales, for which one wants to display
the sum (see section ”SUM OF THE SELECTED SCALES”).
- Allow to scroll backwards in the menu steps or in the parameters inside a step.
- In the numeric or alphanumeric input phase, it increments the blinking digit.
F8
- If pressed for an instant it allows printing and resetting the partial total.
- In the numeric or alphanumeric input phase, it selects the digit to be modified from right to left.
F9
- If pressed for an instant it allows printing and resetting the general total.
- In the numeric or alphanumeric input phase, it selects the digit to be modified from left to right.
F10
- If pressed for an instant, it executes the printing and the zeroing of the grand total.
- In the numeric or alphanumeric input phase, introduces a space between two characters.
NUMERIC
KEYBOARD
- Entry of digits or characters.
- During the weighing, these enter a numeric value with which it’s possible to:
1)
Set the tare value, by pressing then the
TARE
key (see section “TARE FUNCTIONS”).
2)
To add or to subtract to the current tare the result of the operation between two values enterable
with the keyboard (See the “CALCULATOR”
section).