63
If the grader is not used for about one year, hydraulic oil will be changed in the
transmission, driving box of rear axle, tandem box and circle worn gear of the blade at
the same time and change engine oil (see item 8.3.1).
1.
Clean piston rod completely and fill lubricating oil into all oil cups.
2.
Carryout inspection as follows:
Check oil levels in the engine, transmission, tandem box of rear axle,
turbine box of blade rotating and hydraulic tank.
Check the air pressure of the tyres.
9. Fault analysis and troubleshooting
As to the maintenance contents listed in the following column of
“Troubleshooting”, we suggest that you had better notify the Sales & Service Dept. of
the manufacturer when you consider the maintenance, since our maintenance workers
are all specially trained, and have special tools to ensure the repairs can be done
correct and skilled.
Note:
Welding of the bearing structural parts on the grader can be only
undertaken by our Sales & Service Dept. or done in our factory to ensure the structure
strength. It is unallowed to weld on the bridge and strictly forbidden to connect the
earth wire of the welding appliance to the bridge.
Fault symptom, analysis of causes and trouble shooting
Faults Possible
causes
Remedies
1. Problem in fuel system
a. Air in the fuel system
b. Fuel system blocked
c. No oil supply or intermittent
oil supply
d. Abnormal injection of the fuel
injector
e. Incorrect advance angle of
fuel supply
Bleed air in fuel system with fuel
delivery pump and check the
system for air leakage.
Dissemble and clean.
Check and repair.
Check the spraying condition of
the fuel injector.
Check and adjust.
1.
Diesel engine
1.1 Diesel engine
fails to start
2.
Deficiency in compression
pressure
a.
Piston ring worn out
b.
Piston ring gumming
c.
Valve leakage.
d. Too low compression
temperature
Replace the piston ring
Remove the gumming
Valve spring broken, elastic
force decreased, improper valve
clearance or bad airproof of
valve connoid, adopt
corresponding solutions.
Low ambient temperature, adopt
methods like preheating to solve.