www.dimplex.de 452164.66.03 · FD 9211
EN-9
English
LA 11MAS - LA 16MAS
11 Device Information
1
Type and order code
LA 11MAS
LA 16MAS
2
Design
2.1
Controller
External
External
2.2
Thermal energy metering
-
-
2.3
Installation location / degree of protection according to EN 60529
Outdoor / IP24
Outdoor / IP24
2.4
Performance levels
1
1
2.5
Frost protection condensate tray / heating water
1
1. The heat circulating pump and the heat pump manager must always be ready for operation.
Heated / yes
Heated / yes
3
Operating limits
3.1
Heating water flow / return
2
°C
2. At air inlet temperatures of -25 °C to -15 °C flow temperature rising from 45 °C to 55 °C
up to 55 ± 2 / from 18
up to 55 ± 2 / from 18
Air (heat source)
°C
-25 to +35
-25 to +35
4
Performance data / flow rate
3
3. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, start-up and operation can be
found in the respective sections of the installation and operating instructions. The specified values have the following meaning, e.g. A7 / W35: Heat source temperature 7 °C and
heating water flow temperature 35 °C.
4.1
Heating water flow rate / internal pressure differential
maximum
m³/h / Pa
1,7 / 7600
2,6 / 14800
minimum
m³/h / Pa
0.7/ 1600
1.2/ 4900
4.2
Heat output / COP
4
4. With maximum heating water flow.
EN 14511
EN 14511
at A-7 / W35
kW / ---
5.7 / 2.8
9.8 / 2.6
at A2 / W35
kW / ---
7.9 / 3.4
11.9 / 3.1
at A7 / W35
kW / ---
9.5 / 3.9
14.5 / 3.7
at A7 / W55
kW / ---
8.2 / 2.9
13.5 / 2.4
at A10 / W35
kW / ---
10.4 / 4.2
15.5 / 3.9
4.3
Sound power level according to EN 12102
Normal operation/reduced operation
5
dB(A)
5. The heat output is reduced by approx. 5 % in lower operation
63 /61
64 / 61
4.4
Sound pressure level at a distance of 10 m
6
Normal operation/reduced operation
5
dB(A)
6. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
33 / 31
34 / 31
4.5
Air flow
m³/h
3000
4500
5
Dimensions, connections and filling quantities
5.1
Device dimensions without connections
7
H x W x L mm
7. Please note that additional space is required for pipe connections, operation and maintenance.
1340 x 852 x 1050
1550 x 852 x 1074
5.2
Device connections for heating system
Inches
R1"
R1"
5.3
Weight of the transportable unit(s) incl. packaging
kg
189
229
5.4
Refrigerant; total filling weight
type / kg
R404A / 3.8
R404A / 3.8
5.5
Lubricant; total filling quantity
type / litres
Polyolester (POE) / 1.3
Polyolester (POE) / 1.9
6
Electrical connection
6.1
Supply voltage; fuse protection
1~/N/PE 230 V (50 Hz) / C20 A
1~/N/PE 230V (50 Hz) / C32 A
6.2
Starting current with soft starter
A
29
45
6.3
Nominal power consumption A2 W35/ max. power consumption
3
kW
2.3 / 3.6
3.8/ 6.1
6.4
Power consumption ventilator
W
up to 85
up to 180
6.5
Nominal current at A2 / W35 / cos
A / ---
12.5 / 0.8
20.7 / 0.8
6.6
Max. power consumption of compressor protection (per compressor) W
-
-
7
Complies with the European safety regulations
8
8. See CE declaration of conformity
8
8
Additional model features
8.1
Type of defrosting
Reverse circulation
Reverse circulation
8.2
Max. operating overpressure (heat source/heat sink)
bar
3.0
3.0