5.1.5.2.2. The "Standard" communication mode

The  standard  operation  works  only  in  connection  with  an  RS485  interface  and  is  a  point  to  point
communication.  This  means  that  only  two  devices  can  be  connected  (  e.g.  DC90  and  DC50/51
terminal). Since this mode does not support protocol security, it may only be used for testing purposes.

5.1.5.2.3. The "Multiuser" communication mode

On the contrary to the "

Cam-BUS

" mode, it is 

not

 possible to operate several devices like e.g. the

CamCon Terminal DC51/T4, the daughter display CD10 or the PC on the RS485 BUS.

5.1.5.2.4. The "S5 - L1" communication mode

This setting is necessary to program a cam controller set to the Siemens "

S5 - L1

" BUS. This is a point

to point communication, meaning that only the CamCon Terminal and the CamCon cam controller can
be connected.

5.1.5.2.5. The "3964R" communication mode

This setting is necessary to program a cam controller set to the "

3964R

" communication mode. This is

a point to point communication, meaning that only the CamCon Terminal and the CamCon cam-switch
can be connected.

5.1.6. Menu "5 Terminal Language"

If  you  selected  the  menu  point  "Language"  in  the  main
menu, you enter the menu for the selection of the terminal
language.  Here  you  can  select  the  desired  language  with
the keys 

 and 

 and cornfirm it with the 

 key.

Note:

The  language  settings  of  the  CamCon  Terminal  and  the  CamCon  cam  controllers  operate
independently,  so  changing  the  language  of  the  CamCon  Terminal  does  not  automatically
change the language of the CamCon cam controller.

5.1.6.1. submenu "device group"

Here  you  can  mark  the  devices,  which  in  the  program
selection  to  participate  (see  chapter  5.1.3.  Menu  "2
Programme selection" on page 9). With the unit number of
the  terminal  appears  instead  of  the  number  "--".  With  the
keys  

 , 

 , 

 and 

 can you a unit number select.

With  that 

 key  You  select  the  unit  numbers,  which  are

to belong to the group. These are then marked with a "#"
behind  the  unit  number.  If  you  marked  inadvertently  a

wrong unit number, then you waive the marking with the key 

 again.

With the key 

 you come back to the terminal configuration.

Version: Jul. 04

Page: 11

  2 rue René Laennec 51500 Taissy France

 

Fax: 03 26 85 19 08,  Tel : 03 26 82 49 29

 

E-mail:[email protected]

Site web : www.hvssystem.com

 

 

 

 

 

 

 

 

 

 

 

Содержание CamCon DC51/T

Страница 1: ...en Tel 49 7022 40590 0 Fax 10 Auf der Langwies 1 D 65510 Hünstetten Wallbach Tel 49 6126 9453 0 Fax 42 Internet http www digitronic com E Mail mail digitronic com 2 rue René Laennec 51500 Taissy France Fax 03 26 85 19 08 Tel 03 26 82 49 29 E mail hvssystem hvssystem com Site web www hvssystem com ...

Страница 2: ...istics and damages which were caused deliberately or through negligence Protection The CamCon DC51 T and this instruction manual are protected by copyright All rights are reserved Neither the CamCon DC51 T nor this document may be copied as a whole or partially photocopied reproduced translated or transferred to electronic media of any kind or into machine readable format without prior written per...

Страница 3: ...de 11 5 1 5 2 5 The 3964R communication mode 11 5 1 6 Menu 5 Terminal Language 11 5 1 6 1 submenu device group 11 5 1 6 2 Submenü Key code administration 12 6 Technical data 12 7 Key word table 13 1 Introduction The CamCon Terminal DC51T is a graphic programming unit for cam controllers of the CamCon family As a standard the CamCon Terminal is equipped with background ilumination and an RS485 inte...

Страница 4: ...st be done in a cold state The connection cables e g for the measuring system or the serial interface must be wired with covers and the covers have to grounded on both ends Analog signals must also be wired with covers and the covers have to be grounded on one end 2 1 Dimensions front door can be locked cutout as per connection clip Fig Drawing to help with the installation of the CamCon Terminal ...

Страница 5: ...n of the serial interface You can specify the type of the serial interface RS232 or RS485 with your order Depending on the type of serial interface the connections and the wiring change DC51 T4 RS485 DC51 T2 RS232 3 1 2 1 Pin allocation of the serial RS232 interface DSUB 9 pinboard RS232 Interface for PC attachment max 15m cable length Pin 1 4 Do not connect Pin 2 TXD Pin 3 RXD Pin 5 GND Pin 6 9 N...

Страница 6: ...t number 60 with bridged close down resistors CamCon DC16 Unit number 1 without bridged close down resistors without bridged close down resistors Unit number 2 CamCon DC16 with bridged close down resistors interface converter PC Note The pins 1 and 2 as well as the pins 3 and 4 have to be bridged in the attachment plug of the first and last device in a networked chain at the RS485 Interface to clo...

Страница 7: ...well as the unit number is displayed in the top line of the main menu Attention The unit or device numbers may only be allocated once on an CamCon RS485 BUS Main menu CamCon Terminal The main menu is the starting point of the operation You can select the desired menu by pressing the corresponding numeric key or by moving the black beam on the desired menu point with the keys and and confirming you...

Страница 8: ...er as described in the corresponding handbooks To break the connection between Terminal and cam controller leave any current submenu of the cam controller by pressing the key Back in the main menu press and hold down the key for about 2 seconds and return to the main menu of the CamCon Terminal Note If you use the CamCon Terminal with several CamCon cam controllers on one RS485 BUS you have to con...

Страница 9: ...ext program 1 in device 4 is selected After completion of the program selection a message appears If an error message appears then program selection was not possible and is again to be implemented Possible sources of error are wrong device numbers or errors in the wiring of the serial interface The program selection can be left at any time by operation of the key 5 1 4 Menu 3 Unit list Select this...

Страница 10: ... next chapter Press the key once to return to the main menu 5 1 5 2 The communication mode or terminal mode Ser Mode The CamCon Terminal offers five different communication modes These are 1 Cam BUS 2 Standard 3 Multiuser 4 S5 L1 and 5 3964R If a specific mode is selected make sure that every device with which you want to communicate supports that communication mode Please note that you have the o...

Страница 11: ...he CamCon Terminal and the CamCon cam switch can be connected 5 1 6 Menu 5 Terminal Language If you selected the menu point Language in the main menu you enter the menu for the selection of the terminal language Here you can select the desired language with the keys and and cornfirm it with the key Note The language settings of the CamCon Terminal and the CamCon cam controllers operate independent...

Страница 12: ...play 128 x 64 pixels with background illumination Interface RS485 up to max 1000m or RS232 up to max 15m Supply voltage 24V DC 20 Current absorbtion about 300mA Connections for Interface via D SUB 9 Voltage supply via plug block pins Dimensions see chapter 2 1 Dimensions on page 4 Operating temperature 0 C 55 C Switchboard normencasement DIN 43700 144 x 144 x 55mm WxHxD Weight about 700g Version J...

Страница 13: ...ministration 12 LCD contrast setting 8 Main menu 7 Menu 1 Start Terminal 8 Menu 2 Programme selection 9 Menu 3 Unit list 9 Menu 4 Terminal config 10 Menu 5 Terminal Language 11 millenium 2 Operation of the CamCon Terminal 7 PDF File 2 Pin allocation 5 Pin allocation of the voltage supply 5 programm selection 11 Serial interface 5 Serial RS232 interface 5 Serial RS485 interface 6 Table of contents ...

Отзывы: