5.1.5.2.2. The "Standard" communication mode
The standard operation works only in connection with an RS485 interface and is a point to point
communication. This means that only two devices can be connected ( e.g. DC90 and DC50/51
terminal). Since this mode does not support protocol security, it may only be used for testing purposes.
5.1.5.2.3. The "Multiuser" communication mode
On the contrary to the "
Cam-BUS
" mode, it is
not
possible to operate several devices like e.g. the
CamCon Terminal DC51/T4, the daughter display CD10 or the PC on the RS485 BUS.
5.1.5.2.4. The "S5 - L1" communication mode
This setting is necessary to program a cam controller set to the Siemens "
S5 - L1
" BUS. This is a point
to point communication, meaning that only the CamCon Terminal and the CamCon cam controller can
be connected.
5.1.5.2.5. The "3964R" communication mode
This setting is necessary to program a cam controller set to the "
3964R
" communication mode. This is
a point to point communication, meaning that only the CamCon Terminal and the CamCon cam-switch
can be connected.
5.1.6. Menu "5 Terminal Language"
If you selected the menu point "Language" in the main
menu, you enter the menu for the selection of the terminal
language. Here you can select the desired language with
the keys
and
and cornfirm it with the
key.
Note:
The language settings of the CamCon Terminal and the CamCon cam controllers operate
independently, so changing the language of the CamCon Terminal does not automatically
change the language of the CamCon cam controller.
5.1.6.1. submenu "device group"
Here you can mark the devices, which in the program
selection to participate (see chapter 5.1.3. Menu "2
Programme selection" on page 9). With the unit number of
the terminal appears instead of the number "--". With the
keys
,
,
and
can you a unit number select.
With that
key You select the unit numbers, which are
to belong to the group. These are then marked with a "#"
behind the unit number. If you marked inadvertently a
wrong unit number, then you waive the marking with the key
again.
With the key
you come back to the terminal configuration.