2. Installation
The unit is inserted into a cutout for front plate installation (see chapter "2.1. Dimensions" on page 4).
Connect the groundig pins on the back of the encasement as well as the cable cover to a grounding
point of the switchboard door in the shortest possible way. All cable connections must be done in a
cold state! The connection cables, e.g. for the measuring system or the serial interface, must be wired
with covers, and the covers have to grounded on both ends. Analog signals must also be wired with
covers, and the covers have to be grounded on one end.
2.1. Dimensions
front door
can be locked
cutout as per
connection clip
Fig.: Drawing to help with the installation of the CamCon Terminal
Version: Jul. 04
Page: 4