background image

D-FORCE1400VA SLIDING GATE OPERATOR

8. Programming Process

Adjust the DIP switch

see Fig13B and table 1

1    2     3     4

1    2     3     4

1    2     3     4

1    2     3     4

                 Fig. 13A            Fig.13B

                                           

17

Содержание D-FORCE1400VA

Страница 1: ...Sliding Gate Operator User s Manual D FORCE1400VA...

Страница 2: ...operator The gate operator should be installed by a qualified technician otherwise serious personal injury or property damage may occur When opening or closing the gate do not attempt to walk or drive...

Страница 3: ...uitable for the power supply in your area 3 Main technical parameters Type D FORCE1400VA D FORCE1400VAU Power supply 220V 50Hz 110V 60Hz Motor speed 52rpm 62rpm Rated output power of motor 500W Remote...

Страница 4: ...low The gate operator must be installed on the inside of the gate Wall Switch Gate operator Input power Rack Sliding gate Fig 1 Gate preparation Be sure the gate is properly installed and slides smoot...

Страница 5: ...ation Anchors see Fig 2 You can use anchor bolts anchors washers and nuts These anchors must be set into the concrete when it is poured or you can use wedge anchors to fasten the operator Gate operato...

Страница 6: ...on the gate Move the gate manually checking if the rack is resting on the gear and weld the second and third nut Bring another rack element near to the previous one Move the gate manually and weld the...

Страница 7: ...ontally Install the limit block as shown in Fig 5 and Fig 6 The spring limit switch and blocks are used to control the position of the gate Release the gear with the key and push the sliding gate manu...

Страница 8: ...g 4 and Fig 5 The magnetic of limit switch and blocks are used to control the position of the gate Release the gear with the key and push the sliding gate manually to pre determine the position fix th...

Страница 9: ...OR Gear Sliding gate Rack Limit block Magnetic Magnetic limit Fig 5 M6X10 Spring limit Magnetic limit Fig 6 Manual operation In case of power failure use release key unlock the lock clockwise is unloc...

Страница 10: ...manually Note If the gate bumps the mounting post and cannot be electric opened move the gate a few inches by hand thus you can release the gate with the key open and close the gate manually Fig 7 6 W...

Страница 11: ...U3 U2 VDR1 Q3 J2 HALL U1 J5 X1 J4 POWER MOTOR Cautionlight ProtectEarth Capacitor Extralbutton switch O S C switch Pedestrianswitch Infared sensor Loopdetector Limit swtich 12VDC GND COM COM COM Learn...

Страница 12: ...r 12 24V AC DC TX Emitter connecting power supply 7 9 8 Control board Terminal J5 Fig 9 infrared Schematic diagram d Three button switch single button switch keypad The D FORCE1400VA is equipped with...

Страница 13: ...6 1 2 3 terminal J2 4 5 6 1 2 3 Fig 10A e Pedestrian switch Connect pedestrian switch wire to 4 and 6 terminal of J2 press the switch the door will open 1 meter when the door is closed terminal J2 Swi...

Страница 14: ...nnect wire see the Fig 11A terminal J2 LOOP 10 11 Control board terminal block Loop detector 12 7 8 9 detector output Fig 11A The car through the loop the door will close itself when the door opened T...

Страница 15: ...tput force adjustment to keep safe usage Clockwise rotation to increase counter clockwise rotation to reduce Warning Motor force can not be set too large just drive the door is ok Remote control The r...

Страница 16: ...bout 2 seconds and then turn off again The learning process is finished Up to 25 remote controls may be used Erase remote controls To erase all existing remote controls press and hold learn button S1...

Страница 17: ...D FORCE1400VA SLIDING GATE OPERATOR 8 Programming Process Adjust the DIP switch see Fig13B and table 1 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Fig 13A Fig 13B 17...

Страница 18: ...IDING GATE OPERATOR 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Fig 13C Fig 13D Table 1 DIP switch adjust DIP DIP switch Function SET 1 ON see Fig 13A No soft start mode OFF see Fig 13A Soft start mode need to po...

Страница 19: ...tion is not allowed during setting If your device responds to your requested function correctly you have set the function successfully otherwise repeat the above setup instruction until your device re...

Страница 20: ...ly stop the gate in the opened and closed positions If the gate stops at opened position when the limit switch is reached the gate will not move if you press OPEN button If the gate stops at closed po...

Страница 21: ...e switch is connected the LED will light k LED 12 indicate the Open limit switch status if the switch is connected the LED will light All these LED position see the Fig 8 10 Maintenance Check the door...

Страница 22: ...s obstructed 2 Infrared sensor function is enabling but the sensor has not been installed 1 Remove obstructions 2 Make sure the infrared sensor function is disabling Remote transmitter does not work 1...

Страница 23: ...an unpack inspection in which you should check whether the product was damaged If you have any problem please contact our dealer You should find the following items in our standard packing N o Item Q...

Отзывы: