![Digital Systems DSF22 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/digital-systems/dsf22/dsf22_installation-and-setup-manual_2499563035.webp)
DSF22
UNIQUE MONITORING TERMINAL
35
INSTALLATION AND SETUP GUIDE
P61 Vehicle engine status report
Description
This parameter enables/disables vehicle engine status report. If report is
enabled, terminal measures
vehicle’s on board voltage level, in case if it
reaches 13 volts (12V mode) or 26 volts (24V mode), terminal sets special
flag bit in status register, that will be sent to the monitoring server.
Otherwise this flag bit will be cleared.
Options
Parameter can be read and modified.
Used values
0
–
Engine status report disabled
1
–
Engine status report enabled in 12V mode
2
–
Engine status report enabled in 24V mode
Default value
0
Comments
Example
To read parameter:
GET P61
To set parameter:
SET P61 2
Response from device:
P61: 2
P62 Digital input changes SMS alert
Description
This parameter enables/disables SMS alert for digital input (DIN). If
parameter set to 1, SMS alert will be sent right after digital input will be
changed from low to high. In case if parameter set to 2, SMS alert will be
sent right after digital input will be changed from high to low.
Options
Parameter can be read and modified.
Used values
0
–
SMS alert disabled
1
–
SMS alert will be sent whet input change from low to high
2
–
SMS alert will be sent whet input change from high to low
Default value
0
Comments
SMS alert will be triggered and sent only if ignition is switched OFF
Example
To read parameter:
GET P62
To set parameter:
SET P62 2
Response from device:
P62: 2