RSTGSM
Reset GSM module
Set
No
-
RSTGPS
Reset GPS module
Set
Yes
-
RESET
Reset device
Set
No
-
FUEL
Read actual ADC measurement
Read
Yes
-
TX1
SMS alert text 1
Read and Set
Yes
See description
TX2
SMS alert text 2
Read and Set
Yes
See description
TX3
SMS alert text 3
Read and Set
Yes
See description
TX4
SMS alert text 4
Read and Set
Yes
See description
Description of parameters.
This section describes all parameters used in terminal. Each parameter can be accessed by SMS
commands, in case of need, parameter can be modified. Almost all parameters are stored in the non-
volatile memory, in case if power loss parameter value will not be changed.
P10 APN name
Description
APN (Access Point Name), used to established GPRS communication. APN
is provided by GSM operator.
Options
Parameter can be read and modified.
Used values
Any ASCII characters, maximal length 32 bytes
Default value
internet
Example
To read parameter:
GET P10
To set parameter:
SET P10 internet
Response from device:
P10: internet
P11 IP address
Description
Server IP address to send all data.
Options
Parameter can be read and modified.
Used values
String of digits, separated by dots.
Default value
195.13.191.180
Example
To read parameter:
GET P11
To set parameter:
SET P11 192.168.100.101
Response from device:
P11: 192.168.100.101