![Digital Systems DSF22 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/digital-systems/dsf22/dsf22_installation-and-setup-manual_2499563026.webp)
DSF22
UNIQUE MONITORING TERMINAL
26
INSTALLATION AND SETUP GUIDE
P31 Fuel data source
Description
This parameter defines a data source used to manage fuel consumption.
Terminal will use selected source to acquire fuel data and send to server.
Options
Parameter can be read and modified.
Used values
0
–
Specialized fuel sensor input used to get fuel data
1
–
External analog input used to get fuel data
Default value
0
Comments
Example
To read parameter:
GET P31
To set parameter:
SET P31 1
Response from device:
P31: 1
P32 Fuel measurement frequency
Description
This parameter defines a fuel measurement frequency during driving time
(Ignition is switched ON). Each unit equals to 32 milliseconds, if necessary
to calculate exact measurement frequency, use following formula:
Example 1
-
To set measurement frequency once per second
1 second = 1000 milliseconds
1000/32 = 32.25 - used value must be
32
Example 2
-
To set measurement frequency once per 5 seconds
5 seconds = 5000 milliseconds
5000/32 = 156.25 - used value must be
156
Options
Parameter can be read and modified.
Used values
10-250
Default value
15
Comments
Example
To read parameter:
GET P32
To set parameter:
SET P32 50
Response from device:
P32: 50